Parameter
Communication operation and setting
FR-E700 SC EC/ENE
6 - 229
6.19
Communication operation and setting
6.19.1 PU
connector
Using the PU connector, you can perform communication operation from a personal computer etc.
When the PU connector is connected with a personal, FA or other computer by a communication ca-
ble, a user program can run and monitor the inverter or read and write to parameters.
Purpose
Parameters that must be set
Refer to
Section
To start operation via communication
Initial setting of operation via
communication
Pr. 342, Pr. 349,
Pr. 501, Pr. 502
Communication operation from
PU connector
Initial setting of computer link
communication (PU connector)
Pr. 117–Pr. 124
Modbus®-RTU communication
specification
Pr. 117, Pr. 118,
Pr. 120, Pr. 122,
Pr. 343, Pr. 502
Pr. 549
Restrictions on parameter write
through communication
Communication E²PROM write selection
Pr. 342
Communication using USB
(FR Configurator)
USB communication
Pr. 547, Pr. 548
To communicate via Ethernet
connector
Initial setting of Ethernet communication
Pr. 442–Pr. 445,
Pr. 805–Pr. 812,
Pr. 830–Pr. 835,
Pr. 837–Pr. 852
CC-Link IE Field Network Basic
Pr. 541, Pr. 544
Fig. 6-109:
PU connector pin-outs
I001935E
Pin Number
Name
Description
1)
SG
Earth (Ground) (connected to terminal 5)
2)
—
Operation panel power supply
3)
RDA
Inverter
4)
SDB
Inverter send
5)
SDA
Inverter send+
6)
RDB
Inverter receive
7)
SG
Earth (Ground) (connected to terminal 5
8)
—
Operation panel power supply
Tab. 6-66:
PU connector (terminal description)
NOTES
Pins No. 2) and 8) provide power to the operation panel or parameter unit. Do not use these pins
for RS-485 communication.
Do not connect the PU connector to the computer's LAN board, FAX modem socket or telephone
modular connector. The product could be damaged due to differences in electrical specifications.
1) to 8)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......