Motor brake and stop operation
Parameter
6 - 108
햲
The input signal terminal used differs according to the Pr. 180 to Pr. 184 settings.
I001568E
Fig. 6-46:
Connection example
I001569E
Fig. 6-47:
Switching to the stop-on contact control mode
햲
햲
햲
햲
Forward rotation command
High-speed operation command
Middle-speed operation command
Stop-on contact selection 0
Stop-on contact selection 1
MC
Mechanical
brake
Motor
MCCB
Power supply
Pr. 4
Pr. 5
Pr. 6
Normal mode
Stop-on-contact control mode
Time
Output fr
equenc
y
ON
ON
ON
ON
OFF
OFF
OFF
* Goes into stop-on-contact control when both RL and RT
switch on. RL and RT may be switched on in any order with any
time difference.
(a): Acceleration time (Pr. 7)
(b): Deceleration time (Pr. 8)
(c): Second deceleration time (Pr. 44/Pr. 45)