Parameter
Communication operation and setting
FR-E700 SC EC/ENE
6 - 261
●
Fault data
Refer to section 7.1 for details of alarm description.
쑶
Data
Description
Data
Description
Data
Description
H00
No fault present
H70
E.BE
HC7
E.AIE
H10
E.OC1
H80
E.GF
HC8
E.USB
H11
E.OC2
H81
E.LF
HC9
E.SAF
H12
E.OC3
H90
E.OHT
HD8
E.MB4
H20
E.OV1
HA0
E.OPT
HD9
E.MB5
H21
E.OV2
HA1
E.OP1
HDA
E.MB6
H22
E.OV3
HB0
E.PE
HDB
E.MB7
H30
E.THT
HB1
E.PUE
HF1
E.1
H31
E.THM
HB2
E.RET
HF5
E.5
H40
E.FIN
HB3
E.PE2
HF6
E.6
H52
E.ILF
HC0
E.CPU
HF7
E.7
H60
E.OLT
HC5
E.IOH
HFD
E.13
Tab. 6-82:
Fault data
Example
쑴
Fault description display example (instruction code: H74)
I002068E
Fig. 6-131:
Fault example
Previous fault
(H30)
Latest fault
(HA1)
For read data = H30A1
previous fault .................. THT
latest fault......................... OP1
Summary of Contents for fr-e700 series