Parameter
Adjust the output torque (current) of the motor
FR-E700 SC EC/ENE
6 - 43
6.3.4
Slip compensation (Pr. 245 to Pr. 247)
When V/F control or general-purpose magnetic flux vector control is performed, the inverter output
current may be used to assume motor slip to keep the motor speed constant.
The above parameters can be set when Pr. 160 "User group read selection" = 0.
Slip compensation is validated when the motor rated slip calculated by the following formula is set to
Pr. 245. Slip compensation is not made when Pr. 245 = 0 or 9999.
Pr. No. Name
Initial Value
Setting Range
Description
Parameters referred to
Refer to
Section
245
Rated slip
9999
0.01–50%
Rated motor slip.
1
3
Maximum frequency
Base frequency
0/9999
No slip compensation
246
Slip compensation time constant
0.5 s
0.01–10 s
Slip compensation response time. When the
value is made smaller, response will be
faster. However, as load inertia is greater, a
regenerative overvoltage fault (E.OV
첸
) is
more liable to occur.
247
Constant-output region slip
compensation selection
9999
0
Slip compensation is not made in the
constant power range (frequency range
above the frequency set in Pr. 3)
9999
Slip compensation is made in the constant
power range.
NOTES
When performing slip compensation, the output frequency may become greater than the set fre-
quency. Set the Pr. 1 "Maximum frequency" value a little higher than the set frequency.
Slip compensation is always valid when advanced magnetic flux vector control is selected, the Pr.
245 to Pr. 247 settings are invalid.
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Rated slip
Synchronous speed at base frequency
Rated speed
–
Synchronous speed at base frequency
----------------------------------------------------------------------------------------------------------------------------------------------- 100%
=
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......