Parameter
CC-Link IE Field Network Basic
FR-E700 SC EC/ENE
6 - 367
Setting the operation mode
The following explains a program to write various data to the inverter.
The following explains a program to change the operation mode of station 1 inverter to network
operation.
●
Operation mode write code: HFB (hexadecimal)
●
Network operation set data: H0000 (hexadecimal) (Refer to page 6-361)
●
The reply code (RWr2) at the time of instruction code execution is set to D2.
(For information about the reply code (RWr2) refer to page 6-360.)
I003130E
Abb. 6-178:
Program example 2
(0)
SM1536
SD1536.0
SD1540.0
M0
(4)
M0
X20
PLS
M300
(8)
M300
SET
M301
10)
M301
X100F
MOV
H0FB
W102
MOV
H0
W103
SET
Y100F
RST
M301
SET
M302
19)
M302
X100F
MOV
W2
D2
RST
Y100F
RST
M302
25)
END
Check the data link status of the station 1
Write operation mode write code (HFB) to
RWw2 and set data (H0000) to RWw3.
Turn on the instruction code execution request
(RY0F)
Read reply code (RWr2) to D2 when the instruction
code execution completion (RX0F) turns on.
Turn off the instruction code execution request
(RY0F)