Special operation
Parameter
6 - 306
Dancer control block diagram
햲
The main speed can be selected from all operation mode such as external (analog voltage input,
multi-speed), PU (digital frequency setting), communication (RS-485, CC-Link).
Set point and measured value of PID control
I001840E
Fig. 6-157:
Dancer control block diagram
Input
Input Signal
Pr. 267
Current/Voltage Input
Switch
Set point
Pr. 133
0–100%
—
—
Measured
value
When measured value is
input as current (4 to
20 mA).
4 mA ... 0%, 20 mA ... 100%
0
When measured value is
input as voltage (0 to ±5 V
or 0 to ±10 V).
0 V ... 0%, 5 V ... 100%
1
0 V ... 0%, 10 V ... 100%
2
Tab. 6-115:
Set point and measured value of PID control
NOTES
Changing the terminal function using any of Pr. 178 to Pr. 184 may affect the other functions. Make
setting after confirming the function of each terminal.
When the Pr. 267 setting was changed, check the voltage/current input switch setting. Different
setting may cause a fault, failure or malfunction. (Refer to page 6-178 for setting.)
Main speed
command
햲
M
3~
Target frequency
Acceleration/deceleration
of main speed
PID
deviation
Acceleration/
deceleration
PID control
PID feedback
Convert to
0 to 100%
Terminal 4
Potentiometer
Dancer roll position detection
Limit
PID set point
Dancer roll
setting point
Pr. 133
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......