Monitor display and monitor output signals
Parameter
6 - 144
Display set frequency during stop (Pr. 52)
When "100" is set in Pr. 52, the set frequency and output frequency are displayed during stop and op-
eration respectively. (LED of Hz flickers during stop and is lit during operation.).
햲
The set frequency displayed indicates the frequency to be output when the start command is
on. Different from the frequency setting displayed when Pr. 52 = "5", the value based on maxi-
mum/minimum frequency and frequency jump is displayed.
Parameter 52
0
100
During Running/Stop
During Stop
During Running
Output frequency
Output frequency
Set frequency
햲
Output frequency
Output current
Output current
Output voltage
Output voltage
Alarm display
Alarm display
Tab. 6-36:
Display during running and stop
NOTES
During an error, the output frequency at error occurrence appears.
During MRS, the values displayed are the same as during a stop.
During offline auto tuning, the tuning status monitor has priority.