MODBUS®/TCP (FR-E700 SC ENE)
Parameter
6 - 346
햲
Writing is available depending on the Pr. 79 and Pr. 340 settings (refer to page Seite 6-218). The
restrictions depending on the operation mode changes according to the computer link
specifications.
●
Real time monitor
For the details of the monitor items, refer to the description of Pr. 52 on page 6-140.
햲
When Pr. 37 is not equal to "0", this will be machine speed display (1 increments).
햳
Input terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "—"
denotes undetermined value.)
햴
Output terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "—"
denotes undetermined value.)
햵
The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained
values.
Mode
Read value
Write value
EXT
H0000
PU
H0001
EXT JOG
H0002
PU JOG
H0003
NET
H0004
H0014
PU+EXT
H0005
Tab. 6-135:
Operation mode / inverter setting
Register
Monitor item
Increment
Register
Monitor item
Increment
40201
Output frequency / machine
speed
0.01 Hz/1
40216
Output terminal status
—
40202
Output current
0.01 A
40220
Cumulative energization time
1 h
40203
Output voltage
0.1 V
40223
Actual operation time
1 h
40205
Frequency setting value /
machine speed setting value
0.01 Hz/1
40224
Motor load factor
0.1 %
40207
Motor torque
0.1 %
40225
Cumulative power
40208
Converter output voltage
0.1 V
40252
PID set point
0.1 %
40209
Regenerative brake duty
0.1 %
40253
PID measured value
0.1 %
40210
Electronic thermal relay
function load factor
0.1 %
40254
PID deviation
0.1 %
40211
Output current peak value
0.01 A
40258 –
40260
For manufacturer check. Do not set.
40212
Converter output voltage peak
value
0.1 V
40261
Motor thermal load factor
0.1 %
40214
Output power
0.01kW
40262
Inverter thermal load factor
0.1 %
40215
Input terminal status
—
40263
Cumulative power 2
0.01 kWh
Tab. 6-136:
Real time monitor items
b15
b0
—
—
—
—
—
RES
—
0
—
RH
RM
RL
—
—
STR
STF
b15
b0
—
—
—
—
—
—
—
—
—
—
ABC
FU
—
—
—
RUN
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......