Parameter
Frequency setting by external terminals
FR-E700 SC EC/ENE
6 - 65
JOG operation from PU
Selects Jog operation mode from the operation panel and PU (FR-PU04/FR-PU07). Operation is per-
formed only while the start button is pressed.
Fig. 6-23:
Connection example for jog operation performed
from PU
I001790E
I001791E
Fig. 6-24:
JOG operation performed from PU
Power
supply
Motor
Inverter
Operation panel
햲
Confirmation of the RUN indication and operation
mode indication.
The monitor mode must have been selected.
The inverter must be at a stop.
햳
Press the PU/EXT key to choose the
PU JOG operation mode.
햴
Press the RUN key.
The motor rotates while the key is pressed.
It rotates at 5 Hz (initial value of Pr. 15).
햵
Release the RUN key to stop the motor.
When changing the frequency of PU JOG operation:
햶
Press the MODE key to choose the parameter
setting mode.
햷
Turn the digital dial until Pr. 15 "JOG frequency"
appears.
햸
Press the SET key to show the currently set value
(5 Hz).
햹
Turn the digital dial to set the value to "10.00"
(10.00 Hz).
햺
Press the SET key to set.
햻
Perform the operations in steps
햲
to
햵
The motor rotates at 10 Hz.
Hold down
Stop
Operation
Display
Release
The parameter number read previously
appears.
Flicker ... Parameter setting complete!
"PRM" indication is lit.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......