Parameter
Communication operation and setting
FR-E700 SC EC/ENE
6 - 259
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from step
햲
again.
쑶
●
List of calibration parameters
Example
쑴
When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0.
Computer Send Data
Inverter Send Data
Description
햲
ENQ 00 FF 0 01 82
ACK 00
Set "H01" to the extended link parameter.
햳
ENQ 00 EC 0 01 7E
ACK 00
Set "H01" to second parameter changing.
햴
ENQ 00 5E 0 0F
STX 00 0000 ETX 25
C3 (Pr. 902) is read. 0% is read.
햵
ENQ 00 60 0 FB
STX 00 0000 ETX 25
C6 (Pr. 904) is read. 0% is read.
Tab. 6-79:
Example for data transmission
Pr.
Name
Instruction
Code
Pr.
Name
Instruction
Code
Read
W
rit
e
Ex
tended
Read
W
rit
e
Ex
tended
C2
(902)
Terminal 2 frequency setting bias
frequency
5E
DE
1
C5
(905)
Terminal 4 frequency setting bias
frequency
60
E0
1
C3
(902)
Terminal 2 frequency setting bias
5E
DE
1
C6
(904)
Terminal 4 frequency setting bias
60
E0
1
125
(903)
Terminal 2 frequency setting gain
frequency
5F
DF
1
126
(905)
Terminal 4 frequency setting gain
frequency
61
E1
1
C4
(903)
Terminal 2 frequency setting gain
5F
DF
1
C7
(905)
Terminal 4 frequency setting gain
61
E1
1
Tab. 6-80:
Calibration parameters
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......