Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 23
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Incr
ease c
ooling
fan life
244
Cooling fan operation
selection
1
1
0
Operates at power on
Cooling fan on/off control invalid
(The cooling fan is always on at power on.)
✔
✔
✔
1
Cooling fan on/off control valid
Slip c
ompensa
tion
245
Rated slip
0.01%
9999
0–50%
Used to set the rated motor slip.
✔
✔
✔
9999
No slip compensation
246
Slip compensation time
constant
0.01 s
0.5 s
0.01–10 s
Used to set the response time of slip
compensation. When the value is made
smaller, response will be faster. However, as
load inertia is greater, a regenerative
overvoltage (E.OV
첸
) error is more liable to
occur.
✔
✔
✔
247
Constant-output region slip
compensation selection
1
9999
0
Slip compensation is not made in the
constant output range (frequency range
above the frequency set in Pr. 3)
✔
✔
✔
9999
Slip compensation is made in the constant
output range.
Gr
ound fault det
ec
tion
249
Earth (ground) fault detection
at start
1
0
0
Without ground fault detection
✔
✔
✔
1
With ground fault detection
Selec
tion of mot
or st
opping method
250
Stop selection
0.1 s
9999
0–100 s
The motor is
coasted to a stop
when the preset
time elapses after
the start signal is
turned off.
STF signal:
Forward rotation start
STR signal:
Reverse rotation start
✔
✔
✔
1000–1100 s
The motor is
coasted to a stop
(Pr. 250 1000) s
after the start
signal is turned
off.
STF signal:
Start signal
STR signal:
Forward/reverse signal
8888
When the start
signal is turned
off, the motor
decelerates to
stop.
STF signal:
Start signal
STR signal:
Forward/reverse signal
9999
STF signal:
Forward rotation start
STR signal:
Reverse rotation start
Tab. 6-1:
Parameter overview (23)
GP
MFVC
GP
MFVC
GP
MFVC
V/FV/FV/F
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......