Installation
Removal and reinstallation of the front cover
FR-E700 SC EC/ENE
2 - 3
Reinstallation
Match the front cover 2 to the inverter front and install it straight.
Insert the two fixed hooks on the lower side of the front cover 1 into the sockets of the inverter.
Tighten the screw of the front cover 1.
I001705E
Fig. 2-4:
Reinstallation of the front cover
NOTES
Fully make sure that the front cover has been reinstalled securely. Always tighten the installation
screws of the front cover.
The same serial number is printed on the capacity plate of the front cover and the rating plate of
the inverter. Before reinstalling the front cover, check the serial numbers to ensure that the cover
removed is reinstalled to the inverter from where it was removed.
Insert hooks into the sockets
Press front cover 2
against the inverter
Tighten the
installation screws
Installation
screws
Front cover 2
Front cover 1
Fixed hook
Socket of the
inverter
Example: FR-E740-230SC