Parameter
Parameter overview
FR-E700 SC EC/ENE
6 - 11
Func-
tion
Parameter
Name
Incre-
ments
Initial
Value
Setting
Range
Description
Para-
meter-
Copy
Para-
meter
Clear
All
Para-
meter
Clear
Refer
to
Page
Rela
te
d
Paramet
ers
✔
: Enabled
—: Disabled
Applied mot
or
71
Applied motor
1
0
0
Thermal characteristics of a standard motor
✔
✔
✔
1
Thermal characteristics of the Mitsubishi
constant-torque motor
40
Thermal characteristic of Mitsubishi high
efficiency standard motor (SF-HR)
50
Thermal characteristic of Mitsubishi constant
torque motor (SF-HRCA)
3
Standard motor
Select "offline auto
tuning setting"
13
Constant-torque
motor
23
Mitsubishi
standard motor
SF-JR 4P
(
1.5 kW)
43
Mitsubishi high
efficiency motor
(SF-HR)
53
Mitsubishi
constant-torque
motor (SF-HRCA)
4
Standard motor
Auto tuning data can
be read, changed, and
set.
14
Constant-torque
motor
24
Mitsubishi
standard motor
SF-JR 4P
(
1.5 kW)
44
Mitsubishi high
efficiency motor
(SF-HR)
54
Mitsubishi
constant-torque
motor (SF-HRCA)
5
Standard motor
Star connection Direct
input of motor
constants is enabled
15
Constant-torque
motor
6
Standard motor
Delta connection Direct
input of motor
constants is enabled
16
Constant-torque
motor
450
Second applied motor
1
9999
0
Thermal characteristics of a standard motor
✔
✔
✔
1
Thermal characteristics of the Mitsubishi
constant-torque motor
9999
Second motor is invalid (thermal
characteristic of the first motor (Pr. 71))
Tab. 6-1:
Parameter overview (11)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......