Appendix
Parameter list with instruction codes
FR-E700 SC EC/ENE
A - 17
—
14
0E
8E
0
Load pattern selection
✔
—
—
Jog operation
15
0F
8F
0
Jog frequency
✔
✔
✔
16
10
90
0
Jog acceleration/deceleration time
✔
✔
✔
—
17
11
91
0
MRS input selection
✔
✔
✔
—
18
12
92
0
High speed maximum frequency
✔
✔
✔
—
19
13
93
0
Base frequency voltage
✔
—
—
Acceleration/
deceleration time
20
14
94
0
Acceleration/deceleration
reference frequency
✔
✔
✔
21
15
95
0
Acceleration/deceleration time
increments
✔
✔
✔
Stall prevention
22
16
96
0
Stall prevention operation level
✔
✔
✔
23
17
97
0
Stall prevention operation level
compensation factor at double speed
✔
✔
✔
Multi-speed setting
24
18
98
0
Multi-speed setting (speed 4)
✔
✔
✔
25
19
99
0
Multi-speed setting (speed 5)
✔
✔
✔
26
1A
9A
0
Multi-speed setting (speed 6)
✔
✔
✔
27
1B
9B
0
Multi-speed setting (speed 7)
✔
✔
✔
—
29
1D
9D
0
Acceleration/deceleration
pattern selection
✔
✔
✔
—
30
1E
9E
0
Regenerative function selection
✔
✔
✔
Frequency jump
31
1F
9F
0
Frequency jump 1A
✔
✔
✔
32
20
A0
0
Frequency jump 1B
✔
✔
✔
33
21
A1
0
Frequency jump 2A
✔
✔
✔
34
22
A2
0
Frequency jump 2B
✔
✔
✔
35
23
A3
0
Frequency jump 3A
✔
✔
✔
36
24
A4
0
Frequency jump 3B
✔
✔
✔
—
37
25
A5
0
Speed display
✔
✔
✔
—
40
28
A8
0
RUN key rotation direction selection
✔
✔
✔
Frequency detection
(SU, FU)
41
29
A9
0
Up-to-frequency sensitivity
✔
✔
✔
42
2A
AA
0
Output frequency detection
✔
✔
✔
43
2B
AB
0
Output frequency detection for reverse
rotation
✔
✔
✔
Second functions
44
2C
AC
0
Second acceleration/deceleration time
✔
✔
✔
45
2D
AD
0
Second deceleration time
✔
✔
✔
46
2E
AE
0
Second torque boost
✔
—
—
47
2F
AF
0
Second V/F (base frequency)
✔
—
—
48
30
B0
0
Second stall prevention operation
current
✔
✔
✔
51
33
B3
0
Second electronic thermal O/L relay
✔
✔
✔
Monitor functions
52
34
B4
0
DU/PU main display data selection
✔
✔
✔
55
37
B7
0
Frequency monitoring reference
✔
✔
✔
56
38
B8
0
Current monitoring reference
✔
✔
✔
Automatic restart
functions
57
39
B9
0
Restart coasting time
✔
✔
✔
58
3A
BA
0
Restart cushion time
✔
✔
✔
—
59
3B
BB
0
Remote function selection
✔
✔
✔
—
60
3C
BC
0
Energy saving control selection
✔
—
—
Function
Parame-
ter
Instruction Code
Name
Control Mode-based Correspondence Table
Refer to
Page
Customer
Setting
Read
W
rit
e
Ext
ended
V/F control
General-pur-
pose magnetic
flux vector
control
Advanced
magnetic flux
vector control
Tab. A-5:
Parameter list with instruction codes (2)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......