Misoperation prevention and parameter setting restriction
Parameter
6 - 196
Write parameters during operation (Pr. 77 = 2)
Parameters can always be written. The following parameters cannot be written during operation if
Pr. 77 = 2. Stop operation when changing their parameter settings.
Parameter
Name
23
Stall prevention operation level compensation factor at double speed
40
RUN key rotation direction selection
48
Second stall prevention operation current
60
Energy saving control selection
61
Reference current
66
Stall prevention operation reduction starting frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity (simple magnetic flux vector control)
81
Number of motor poles
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
90–94
Motor constants
96
Auto tuning setting/status
178–184
Input terminal function selection
190–192
Output terminal function selection
277
Stall prevention operation current switchover
292
Automatic acceleration/deceleration
293
Acceleration/deceleration separate selection
298
Frequency search gain
329
Digital input unit selection
(Parameter for the plug-in option FR-A7AX-Ekit-SC-E)
450
Second applied motor
541
Frequency command sign selection (CC-Link)
(Parameter for the plug-in option FR-A7NC-Ekit-SC-E)
800
Control method selection
859
Torque current
Tab. 6-51:
Parameters that cannot be written during operation
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......