Adjust the output torque (current) of the motor
Parameter
6 - 50
Limit the stall prevention operation and fast-response current limit operation according to the
operating status (Pr. 156)
Refer to the following table and select whether fast-response current limit operation will be per-
formed or not and the operation to be performed at OL signal output:
햲
Since both fast-response current limit and stall prevention are not activated, OL signal and E.OLT
are not output.
햳
The settings "100" and "101" allow operations to be performed in the driving and regeneration
modes, respectively. The setting "101" disables the fast-response current limit in the driving mode.
햴
OL signal is not output at fast-response current limit operation.
Pr. 156
Setting
Fast-Response
Current Limit
햴
Stall Prevention Operation Level
OL Signal Output
Acceleration
Constant speed
Deceleration
Without Alarm
Stop with Alarm
"E.OLT"
0
✔
✔
✔
✔
✔
—
1
—
✔
✔
✔
✔
—
2
✔
—
✔
✔
✔
—
3
—
—
✔
✔
✔
—
4
✔
✔
—
✔
✔
—
5
—
✔
—
✔
✔
—
6
✔
—
—
✔
✔
—
7
—
—
—
✔
✔
—
8
✔
✔
✔
—
✔
—
9
—
✔
✔
—
✔
—
10
✔
—
✔
—
✔
—
11
—
—
✔
—
✔
—
12
✔
✔
—
—
✔
—
13
—
✔
—
—
✔
—
14
✔
—
—
—
햲
햲
15
—
—
—
—
햲
햲
16
✔
✔
✔
✔
—
✔
17
—
✔
✔
✔
—
✔
18
✔
—
✔
✔
—
✔
19
—
—
✔
✔
—
✔
20
✔
✔
—
✔
—
✔
21
—
✔
—
✔
—
✔
22
✔
—
—
✔
—
✔
23
—
—
—
✔
—
✔
24
✔
✔
✔
—
—
✔
25
—
✔
✔
—
—
✔
26
✔
—
✔
—
—
✔
27
—
—
✔
—
—
✔
28
✔
✔
—
—
—
✔
29
—
✔
—
—
—
✔
30
✔
—
—
—
햲
햲
31
—
—
—
—
햲
햲
100 D
햳
✔
✔
✔
✔
✔
—
100 R
햳
—
—
—
—
햲
햲
101 D
햳
—
✔
✔
✔
✔
—
101 R
햳
—
—
—
—
햲
햲
Tab. 6-4:
Setting of parameter 156 (D = Driving, R = Regeneration)
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......