Misoperation prevention and parameter setting restriction
Parameter
6 - 200
Deletion of parameter from user group (Pr. 174)
I001822E
Fig. 6-101:
When deleting Pr. 3 from user group
NOTES
Pr. 77, Pr. 160 and Pr. 991 can always be read, independently of the user group setting.
Pr. 77, Pr. 160 and Pr. 172 to Pr. 174 cannot be registered to the user group.
When Pr. 174 is read, "9999" is always displayed. Although "9999" can be written, no function is
available.
When any value other than "9999" is set to Pr. 172, no function is available.
햲
Confirmation of the RUN indication and
operation mode indication.
The inverter must be at a stop.
The inverter must be in the PU operation mode
(using the PU/EXT key).
햳
Press the MODE key to choose the parameter
setting mode.
햴
Turn the digital dial until P.174 (Pr. 174) appears.
햵
Press the SET key to display "9999".
햶
Turn the digital dial until "3" appears.
햷
Press the SET key to set.
"P.174" and "3" are displayed alternately.
To continue parameter deletion, repeat
steps
햴
to
햷
.
Operation
Display
Flicker ... Deletion of Pr. 3
from user group completed!
Parameter setting mode
Pr. 174 "User group clear" is
displayed.
When Pr. 174 is read, "9999" is
displayed.
Select the parameter number
to be deleted.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......