CC-Link IE Field Network Basic
Parameter
6 - 372
Fault record reading
The following program reads fault records of station 1 inverter to D1.
●
Faults history No. 1, No. 2 reading instruction code: H74 (hexadecimal)
For the error codes, refer to page 7-2.
The reply code at the time of instruction code execution is set to D2.
(For information about the reply code (RWr2) refer to page 6-360.)
Resetting the inverter at inverter error
The following is a program example for resetting station 1 inverter.
I003137E
Fig. 6-184:
Program example 8
I003138E
Fig. 6-185:
Program example 9
NOTES
The above inverter reset using RY1A may be made only when an inverter error occurs.
When Pr. 349 "Communication reset selection" = "0", inverter reset is available independently of
the operation mode.
When using the instruction code execution request (RYF) with the instruction code (HFD) and data
(H9696) to reset the inverter, set a value other than "0" in Pr. 340 "Communication startup mode
selection" or change the operation mode to the network operation mode. (For the program exam-
ple, refer to page 6-367.)
Refer to page 6-243 for operation conditions of inverter reset.
(0)
SM1536
SD1536.0
SD1540.0
M0
(4)
M0
X20
PLS
M300
(8)
M300
SET
M301
(10)
M301
X100F
MOV
H74
W102
SET
Y100F
RST
M301
SET
M302
(17)
M302
X100F
MOV
W3
D1
MOV
W2
D2
RST
Y100F
RST
M302
(25)
END
Check the data link status of the station 1
Read alarm data (RWr3) and reply code (RWr2)
to D1 and D2 when the instruction code
execution completion (RX0F) turns on.
Write error history No.1 and No.2 read code
(H74) to RWw2.
Turn off the instruction code execution request
(RY0F)
Turn on the instruction code execution request
(RY0F)
(0)
SM1536
SD1536.0
SD1540.0
M0
(4)
M0
X101A
X20
Y101A
(8)
END
Check the data link status of the station 1
Turn on the error reset request flag (RY1A)
Turn off the error reset request flag (RY1A)
when the error status flag (RX1A) is off.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......