Operation
Operation panel
FR-E700 SC EC/ENE
4 - 19
I001743E
Fig. 4-14:
Initial value change list
햲
Screen at powering on
The monitor display appears.
햳
Press the PU/EXT key to choose the PU
operation mode.
햴
Press the MODE key to choose the parameter
setting mode.
햵
Turn the digital dial until "Pr.CH" appears.
햶
Pressing the SET key changes to the initial value
change list screen.
햷
Turning the digital dial displays the parameter
number changed.
햸
Press the SET key to read the currently set value.
햹
Turn the digital dial and press the SET key to
change the setting.
햺
Turn the digital dial to read another parameter.
햻
The display returns to "P.---" after all parameters
are displayed.
햽
Pressing the SET key in status "P.---" returns to the
parameter setting mode.
Operation
Display
The parameter number
read previously appears..
Flicker ... Parameter setting complete!
It may take several
seconds for creating
the initial value change
list. "P.--- " flickers while
creating the list.
PU indication is lit.
PRM indication is lit.
앫
Turning the digital dial sets other parameters.
앫
Pressing the SET key displays the change list again.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......