Basic settings
Simple mode parameter list
FR-E700 SC EC/ENE
5 - 13
Selection method of advanced magnetic flux vector control
Fig. 5-9:
Selection method of advanced magnetic flux vector control
NOTES
Uneven rotation slightly increases as compared to the V/F control. (It is not suitable for machines
such as grinding machine and wrapping machine which requires less uneven rotation at low
speed.)
Use Pr. 89 to adjust the motor speed fluctuation at load fluctuation. (Refer to page 6-38.)
Perform secure wiring.
(Refer to section 3.2.)
Set the motor. (Pr. 71) (Refer to page 5-12.)
햲
For other settings of Pr. 71, refer to section 6.8.2.
햳
Refer to section 5.1.8 for offline auto tuning.
Motor
Pr. 71
햲
Remarks
Mitsubishi
Standard motor,
high efficiency
motor
SF-JR
0
Initial value
SF-HR
40
—
Others
3
Offline auto tuning is necessary.
햳
Constant-torque
motor
SF-JRCA 4P
1
—
SF-HRCA 4P
50
—
Others (SF-JRC, etc.)
13
Offline auto tuning is necessary.
햳
Other
manufac-
turer's
Standard motor
—
3
Offline auto tuning is necessary.
햳
Constant-torque
motor
—
13
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 5-12.)
Set the operation command. (Refer to section 5.2.)
Test run
Set motor capacity (kW) in Pr. 80 "Motor capacity" and the number of motor
poles (number of poles) in Pr. 81 "Number of motor poles".
(V/F control is performed when the setting is "9999" (initial value).
Select the start command and speed command.
1) Start command
–
Operation panel: Setting by pressing the RUN key of the
operation panel
–
External command: Setting by forward rotation or reverse
rotation command (terminal STF or STR)
2) Speed command
–
Operation panel: Setting by pressing the digital dial of the
operation panel
–
External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to
terminal 2 (or terminal 4).
–
Multi-speed command:
The external signals (RH, RM, RL) may also be used to give
speed command.
앫
Perform offline auto tuning. (Pr. 96) (Refer to section 5.1.8.)
Select the control method. (Pr. 800)
(Refer to page 5-12.)
Set "20" (initial value) in Pr. 800 to make advanced magnetic flux vector
control valid.
Summary of Contents for fr-e700 series
Page 2: ......
Page 4: ......
Page 20: ...Contents XVI ...
Page 112: ...Operation panel Operation 4 20 ...
Page 154: ...External operation Basic settings 5 42 ...
Page 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Page 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Page 606: ...A 30 Index Appendix ...
Page 607: ......