background image

 

 

 

 

 

Installation Instructions

 

ELEKTROMAT 
SIK 25.10-30,00

 

Model: 10003999 10012

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 18.01.2022

 

 

 

Summary of Contents for 10003999 10012

Page 1: ...f Installation Instructions ELEKTROMAT SIK 25 10 30 00 Model 10003999 10012 en Status 18 01 2022 ...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de ...

Page 3: ...tch connection 15 10 Emergency manual operation rapid hand chain operator 16 11 Completion of commissioning testing 18 12 Disposal 20 13 Declaration of incorporation Declaration of conformity 21 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required action Schematic representations are based on product example...

Page 4: ...ing of door systems Expert knowledge relevant skills and practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance and modernisation according to the instructions Safe operation The safe operation of the product can only be ensured if it is used as specified Follow the installation instructions Observe all specifi...

Page 5: ... Allow only competent people to carry out the work Disconnect all cables from the power supply Observe valid regulations and standards Use suitable tools Warning Danger to life from falling objects if the drive unit is subjected to impermissible forces Inadmissible forces examples collision with a forklift dropping the drive unit tearing or pulling on the motor lead to damage to the drive unit The...

Page 6: ...ety circuit 24 V Degree of protection IP 54 Temperature range 10 40 60 2 C Operating sound pressure level 70 dB A Maximum output speed OPEN CLOSE for frequency inverter operation 18 10 min 1 Cycles per hour 12 8 3 1 h 1 Max holding torque 250 Nm Locking torque 510 Nm Safety brake testing centre approval number 14 003612 PR02 Manual force emergency manual operation 198 N 1 Specification in accordin...

Page 7: ...ocking torque and the approval number of the safety brake are available in the technical data of these instructions Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the door to drop...

Page 8: ... maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC05001_Z001 ...

Page 9: ...9 Mounting Two elongated holes are provided for mounting BAGAD05001_Z001 ...

Page 10: ...ions of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly grease the door shaft BAGAE05001_Z001 Mount the keys BAGAE05002_Z001 ...

Page 11: ...ttach the drive unit BAGAE05003_Z001 Tighten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE05004_Z001 75 Nm 8 8 8 8 ...

Page 12: ...e energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit switch plug BAHAA02_Z001 BAHAC07_Z001 Completing the electrical installation Mount the cable entries and or cable glands ...

Page 13: ...e final limit positions OPEN and CLOSE is described in the instructions for the door control The door control must meet Performance Level c Use only door controls that evaluate the limit switch according to EN 12543 and meet Performance Level c ...

Page 14: ...14 7 Motor connection M1 Motor X13 Motor plug 8 Alternative motor connection M1 Motor X13 Motor plug ...

Page 15: ...15 9 Limit switch connection F10 Thermal contact S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage ...

Page 16: ...rgency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the door to drop Adopt a secure position For drive units with b...

Page 17: ...17 Switch on by pulling the red handle Open or close by pulling the chain Switch off by pulling the green handle ...

Page 18: ...ng The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door against dropping Please observe the specifications of the door manufacturer The drive unit needs replacement Please observe the specifications of the door manufacturer Mounting Check all mounting el...

Page 19: ...nal limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards ...

Page 20: ...pose of old devices properly according to local legal regulations Return old devices to the return and collection systems available You can also return GfA products free of charge Please apply enough postage to the package and mark it as old devices Notice Environmental damage The gearbox contains oil Ensure proper disposal according to local legal regulations ...

Page 21: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 1 5 1...