background image

CDC-0252-1-TMS+

 

instructions

Please order bracket sets separately 

Summary of Contents for CDC-0252 1-TMS+ Series

Page 1: ...CDC 0252 1 TMS instructions Please order bracket sets separately ...

Page 2: ...shock fire and or serious injury Save all warnings and instructions for future reference Observe maximum pressure load of the chain Maximum pressure load of chain is not automatically identical with maximum pressure force of the drive 100 200 300 400 500 600 700 800 250 300 200 150 100 50 0 Pressure load N Stroke mm Pressure load diagram Scope of supply Drive unit with 2 5 m silicone cable Dependi...

Page 3: ...ity Ambient humidity Emission sound pressure level Additional functions approx 1500 N 20 000 double strokes 30 with cycle time 10 min Aluminium powdercoated RAL 9006 IP 32 5 75 C 30 min 300 C 90 not condensing LpA 35 dB A Closing edge protection activated 3 repetitions of stroke Locking relief activated retraction lift max 0 2 mm Main closing edge Beside closing edge Beside closing edge Closing ed...

Page 4: ...formation 23 mm X Stroke limiting with magnets Voltage must continue to be applied to the drive when moving in the CLOSE direction Hold the magnet next to the drive as shown in the diagramme 2 sec until you hear a pulsating ton The drive is now in learning mode The magnet can now be removed and the drive no longer has to be under voltage Close drive Allow the drive to run OPEN until you reach the ...

Page 5: ...e at D H MechatronicAG D 22949Ammersbek Dirk Dingfelder Maik Schmees Member of the Board Authorized signatory Technical Director 29 01 2018 Maintenance and cleaning Maintenance work is only allowed when the device is in a de energized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H spare parts may be used Repairistobecarriedoutexclusi...

Page 6: ... 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group MOT BK BK OG 2x47kW End mod ul Term inal mod ule Mod ule term inal EM 47 K OG YE GN WH Mot a BN Mot b HS TMS n c CDC 0252 1 TMS GY n c Junction box High Speed High Speed High Speed Mot b BN Mot a WH 24 V DC 24 V DC Monitoring Normal mode SHEV fast running 1 drive Connection PinAssignment 6x 0 5 mm Ø 7 1 0 5 mm WH white BN brown OG orange YE yellow GN green G...

Page 7: ...b 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group MOT BK BK OG 2x47kW End mod ul Term inal mod ule Mod ule term inal EM 47 K OG YE YE GN GN WH BN Mot a Mot b HS HS TMS TMS n c n c CDC 0252 1 TMS CDC 0252 1 TMS GY n c Junction box GY n c BN Mot b WH Mot a Monitoring OG ...

Page 8: ...252 0350 1 TMS CDC 0252 0600 1 TMS CDC 0252 0800 1 TMS A B C Dimensions 30 mm 3 5 m m A Dyer Environmental Controls Ltd Unit 10 Lawnhurst Trading Estate Cheadle Heath Stockport SK3 0SD Tel 44 0 161 491 4840 E Mail enquiry dyerenvironmental co uk www dyerenvironmental co uk ...

Reviews: