Page 2: ...nstallation of motor cables 23 Connection of motor 23 Direction of motor rotation 23 Electrical installation brake cable 24 Electrical installation relay outputs 24 Electrical installation 24 Volt ext...

Page 3: ...ences and limits 59 Parameters Inputs and outputs 68 Special functions 84 Parameters Serial communication 100 Parameters Technical functions and diagnostics 108 Messages 115 Trouble shooting 115 Displ...

Page 4: ...l installation Improper instal lation of the motor or the Holip may cause equipment failure serious injury or death Follow this manual and National Electri cal Codes and local safety codes NOTE Electr...

Page 5: ...e inputs than L1 L2 and L3 when loadsharing linking of DC intermediate circuit and external 24 V DC have been installed Check that all voltage inputs have been discon nected and that the necessary tim...

Page 6: ...LP V Series 5 HLP V series namelate explanation MODEL HLPV4040EBC3DV10 INPUT 3PH380 440V 50 60Hz OUTPUT 3PH380 440V 61A 73A 55 6KVA Freq Range 0 1000Hz HOLIP ELECTRONIC TECHNOLOGY CO LTD Technical dat...

Page 7: ...output Unlimited Ramp times 0 05 3600 sec Torque characteristics Starting torque HLP V 4015 4550V 160 for 1 min Starting torque 180 for 0 5 sec Acceleration torque 100 Overload torque HLP V 4015 4550...

Page 8: ...e level 0 24 V DC PNP positive logics Voltage level logical 0 5 V DC Voltage level logical 1 10 V DC Maximum voltage on input 28 V DC Input resistance Ri 2 k Scanning time per input 3 msec Resolution...

Page 9: ...trol card 50 V AC 1 A 50 VA Max terminal load DC1 on 4 5 control card 25 V DC 2 A 50 V DC 1 A 50 W Max terminal load DC1 on 4 5 control card for UL cUL applications 30 V AC 1 A 42 5 V DC 1A Terminal n...

Page 10: ...pm max error 7 5 rpm Speed accuracy closed loop 1500 rpm max error 1 5 rpm Torque control accuracy open loop 0 150 rpm max error 20 of rated torque Torque control accuracy speed feedback Max error 5 o...