1

Operating elements and connections using as an example the DFPI-100-...

2

1

4

3

9

aJ

5

6
7

8

6

6

6

aA

aB

aC

1

Mounting thread (reverse side,

Fig. 4)

2

Piston rod with mounting thread
for coupling and spanner flat for
counter holding

3

Slot for proximity sensor

4

Representation without flange
receptacle

5

Electrical connection behind the
flange receptacle

6

Thread for mounting the flange
receptacle

7

Earth terminal; position depends
on piston diameter of the drive

8

Pneumatic interface*

)

– channel 4

(extend piston rod)

9

Pneumatic interface*

)

– channel 2

(retract piston rod)

aJ

Electric cable (displacement
encoder)

aA

Optional: connecting cable with
protective conduit (accessories)

aB

Flange receptacle;
shape dependent on the piston
diameter of the drive

aC

Cylinder barrel; version depends
on the piston diameter of the drive

*

)

Pneumatic connection

Fig. 10

Fig. 1

2

Design

The DFPI-...-...-ND2P-E-P-G2 is an electro-pneumatic linear drive consisting of:
– a double-acting pneumatic cylinder with
– integrated displacement encoder (potentiometer) for determining the actual

position.

The displacement encoder supplies an analogue signal proportional to the dis-
placement in the form of a voltage (voltage divider).
If necessary, proximity switches can be installed in the slots (

Fig. 1

3

) in order

to provide binary interrogation of positions as well.

The electric and pneumatic connections are protected against external mechanical
influences by a rugged flange receptacle.
A connecting cable with protective conduit (

Fig. 1

aA

) is available as an access-

ory (

www.festo.com/catalogue).

The product is available in various designs. These operating instructions describe
the following product variants:

Features

Type
codes

Description

Type

DFPI–

Double-acting pneumatic drive for process automation with
integrated displacement encoder

Size of
valve actuator

100–
125–
160–
200–
250–
320–

Piston diameter can be selected in steps;
Specifications in [mm]

Stroke

...–
(40 ... 990)

Stroke length freely selectable in the range from 40 to 990;
specifications in [mm]

Cushioning

N

No cushioning

Displacement
encoder

D2

Integrated analogue displacement encoder

Method of
measurement

P–

Potentiometer

Attachment position
of controller

E–

External (no controller integrated)

Connection type

P–

Protected pneumatic connections

Generation

G2

2nd generation

Fig. 2

Type code (e.g. DFPI-100-200-ND2P-E-P-G2)

The following characteristics of the linear drive are dependent on the piston
diameter, and may differ from the representation shown in Fig. 1:
– Position of the earth terminal (

identification on product),

– Shape of the cylinder barrel
– Shape of the flange receptacle.
In addition, for linear drives with a piston diameter ≥ 200 mm the compressed air
supplied from one side is fed via an unprotected line parallel to the cylinder barrel.
Tie rod screws are used to attach the cylinder end cap. For linear drives with a
piston diameter ≤ 200 mm the compressed air is fed internally. The cylinder end
caps are screwed to the housing.

3

Function

Pressurising and venting of the cylinder
chambers cause the piston rod connec-
ted to the piston to move to and fro.
The integrated displacement encoder
transmits the current position to the
higher-level system as an analogue
signal.

Fig. 3

The process valve (e.g. guided slide gate, penstock valve), which is connected via a
coupling, opens or closes corresponding to the movement of the piston rod. The
cross-sectional area of the piston rod causes differences of force between forward
stroke and return stroke (

www.festo.com/catalogue).

4

Application

The designated use of the DFPI linear drive is to drive linearly actuated, guided
process valves in process automation systems – for example guided gate valve
actuators and penstock valves. It is suitable for use in the process industry in the
area of:
– water,
– sewage,
– industrial process water,
– silage and
– bulk goods technology.
The stroke length of the drive is generally at least equal to the nominal diameter of
the process valve, so that the gate valve actuator can be opened and closed com-
pletely using the DFPI.
The product is tailored to the requirements of the process industry (

catalogue

www.festo.com/catalogue).

Summary of Contents for DFPI-***-***-ND2P-E-P-G2

Page 1: ...meter can be selected in steps Specifications in mm Stroke 40 990 Stroke length freely selectable in the range from 40 to 990 specifications in mm Cushioning N No cushioning Displacement encoder D2 Integrated analogue displacement encoder Method of measurement P Potentiometer Attachment position of controller E External no controller integrated Connection type P Protected pneumatic connections Gen...

Page 2: ...has an initial lubrication which suffices for the complete service life Using lubricated compressed air flushes out the initial lubrication The product may then only be operated with lubricated compressed air Make sure that cut off tube ends are cut off square and are free of burrs This way you prevent damage to internal O rings of the DFPI when the compressed air tubes are inserted Please select ...

Page 3: ...he integrated displacement encoder and to make the sensor signal available Pin Assignment 1 Connection 1 Operating voltage 3 1 2 Output actual value 0 15 V DC 3 Operating voltage 1 Maximum permissible operating voltage 15 V DC Fig 8 6 Carefully plug the wired socket strip onto the plug 7 Refasten the socket strip with the two screws tightening torque 0 5 Nm 10 8 Remount the flange receptacle When ...

Page 4: ...r flat on the piston rod 22 27 36 Design Piston rod cylinder barrel Cushioning No cushioning Mounting position Any Mode of operation Double acting Position sensing With integrated displacement encoder Measuring principle of displacement encoder Potentiometer Operating voltage range V DC 0 15 Max operating voltage V DC 15 Independent linearity FS 0 04 Hysteresis mm 0 33 Repetition accuracy mm 0 12 ...

Reviews: