21-24
Chapter 21
Technical Notes
SJ700D / SJ700B
SJ-P1
Remarks
Display code
Function name
New code
b040
Torque limit selection
bA110
Addition of individual settings for second control
b041
Torque limit 1 (Four-quadrant mode normal
powered)
bA112
Addition of individual settings for second control
b042
Torque limit 2 (Four-quadrant mode reverse
regenerative)
bA113
Addition of individual settings for second control
b043
Torque limit 3 (Four-quadrant mode reverse
powered)
bA114
Addition of individual settings for second control
b044
Torque limit 4 (Four-quadrant mode normal
regenerative)
bA115
Addition of individual settings for second control
b045
Torque LADSTOP selection
bA116
Addition of individual settings for second control
b046
Selection of reversal prevention
HC114
Addition of individual settings for second control
b050
Instantaneous power failure non-stop
selection
bA-30
b051
Instantaneous power failure non-stop
starting voltage
bA-31
b052
Instantaneous power failure non-stop
OV-LADSTOP level (target voltage level)
bA-32
b053
Instantaneous power failure non-stop
deceleration time
bA-34
b054
Instantaneous power failure non-stop
deceleration start range
bA-36
b055
Instantaneous power failure non-stop
proportional gain setting
bA-37
b056
Instantaneous power failure non-stop
integrated time setting
bA-38
b060
Window comparator O upper limit
CE-40
b061
Window comparator O lower limit
CE-41
b062
Window comparator O hysteresis width
CE-42
b063
Window comparator OI upper limit level
CE-43
b064
Window comparator OI lower limit level
CE-44
b065
Window comparator OI hysteresis width
CE-45
b066
Window comparator O2 upper limit level
CE-46
b067
Window comparator O2 lower limit level
CE-47
b068
Window comparator O2 hysteresis width
CE-48
b070
O operation level at disconnection
CE-50
b071
OI operation level at disconnection
CE-52
b072
O2 operation level at disconnection
CE-54
b078
Deletion of integrated power
UA-12
b079
Integrated power display gain
UA-13
b082
Starting frequency
Hb130
Addition of individual settings for second control
b083
Carrier frequency
bb101
Addition of individual settings for second control
b084
Selection of initialization
Ub-01
b085
Initialization data selection
Ub-02
b086
Frequency conversion coefficient
Ab-01
b087
Stop key selection
AA-13
b088
Free-run stop selection
bb-40
b089
Automatic carrier reduction
bb103
Addition of individual settings for second control
b090
BRD use rate
bA-60
b091
Stop mode selection
AA115
Addition of individual settings for second control
b092
Cooling fan operation selection
bA-70
b095
BRD selection
bA-61
b096
BRD on level
bA-62
b098
Thermistor selection
Cb-40
b099
Thermistor error level
bb-70
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...