12-9-23
Chapter 12
Inverter Function
• In this control mode, operations of magnetic-pole
position estimation, IVMS start control, and
sensorless vector control are started in this order.
• In this control mode, only the parameters set by the
first set-up are enabled. Terminal [SET] cannot be
used.
• In the magnetic-pole position estimation, it is
possible to select whether the motor is started after
the motor's magnetic-pole positions are estimated
by use of the initial-position estimation function or
the magnetic-pole positions are synchronized by
use of the DC braking function.
Parameters common to this mode and the
synchronous starting mode
• In the case of starting after the magnetic-pole
position estimation, estimation operation is
conducted at the start by setting the start method
[Hd132] at 01.
• In the case of the start method [Hd132] being set at
00, the magnetic poles are positioned to the output
phases at the start. As a large offset between the
magnetic poles and the output phases may fail the
starting, use the starting-time DB to synchronize
the magnetic-pole positions and the output phases
before the starting.
Item
Parameter
Data
Description
Control mode
[AA121]
12
To use IVMS-start type sensorless vector control
(SM/PMM)
Speed response
[HA115]
0~1000(%)
To adjust the responsiveness of the control.
A larger value enhances the responsiveness.
SM(PMM) lowest
frequency (switch)
[Hd130]
0~50(%)
The frequency at which the sensorless vector
control is started.
Set the ratio to the base frequency [Hd104].
SM(PMM) no-load
current
[Hd131]
0~100(%)
Set the ratio of the no-load current to the rated
current during the sensorless vector control.
SM(PMM) start method
[Hd132]
00
Initial position estimation is disabled.
01
Initial position estimation is enabled.
SM(PMM) initial position
estimation zero-V
stand-by times
[Hd133]
0~255
This is a stand-by adjustment value to stabilize
the reference value for the initial position
estimation detection.
SM(PMM) initial position
estimation detection
stand-by times
[Hd134]
0~255
This is an adjustment value to stabilize the
current rise of the initial position estimation
operation.
SM(PMM) initial position
estimation detection
times
[Hd135]
0~255
This is a detection-operation adjustment value of
the initial position estimation operation.
SM(PMM) initial position
estimation voltage gain
[Hd136]
0~200(%)
This is a output-voltage adjustment gain of the
initial position estimation operation.
SM(PMM) initial position
estimation magnetic-pole
position offset
[Hd137]
0~359(°)
To conduct corrections in a case where the initial
position estimation operation has a certain error.
DC braking selection
[AF101]
01
Internal DC braking: enabled
DC braking force at the
start
[AF108]
0~100(%)
To adjust the DC braking force. Setting of 100%
will provide maximum braking force.
DC braking time at the
start
[AF109]
0.0~60.0(s)
Enabled during the internal DC braking.
When the operation command is turned ON, DC
braking is started.
Over current detection
level
[bb160]
Inverter ND
rated current
×
(0.20 to 2.20)
To Set the level at which the over current is
detected.
A
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...