CAN232 

CAN to RS-232 Interface Converter 

User Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shenzhen 3onedata Technology Co., Ltd 

Tel: +86-755-26702668  Fax: +86-755-26703485 

www.3onedata.com

 

Summarize

 

CAN232 is used for data exchange between CAN-Bus field bus 

and RS-232  bus interface converter, and supports Modbus RTU 

protocol.

 

CAN232 interface converter integrated a RS-232 

channel and a CAN-Bus  channel can be easily embedded using 

RS-232 interface for communication nodes, do not need to change 

the original hardware architecture enables the device to obtain the 

CAN-Bus  communication interface, to achieve between the 

equipments of RS-232 and CAN-Bus  network connection and 

data communication.

 

RS-232 channel CAN232 devices to support 

a variety of baud rate, the range is 300bps~115200bps.

 

CAN-Bus 

channel support CiA recommended a variety of standard baud rate 

and user-defined baud rate, the range of 2.5Kbps~1Mbps. 

CAN232 interface converter provides three types of data 

conversion: transparent conversion, encryption conversion and 

Modbus protocol conversion. 

Its exterior design supports DIN-Rail  mounting and Wall 

mounting, which is convenient for engineering application.

 

The 

board comes with a photoelectric isolation module, complete 

electrical isolation control circuit and CAN-Bus communication 

circuit, so that the CAN232 converter has a strong 

anti-interference ability, greatly improving the system in the harsh 

environment of the use of reliability. 

Packing list

 

The  serial device server  is shipped with the following items. If 

any of these items are missing or damaged, please contact your 

customer service representative for assistance. 

 

Interface Converter 

  1 

 

Documentation and software CD 

  1 

 

User manual 

  1 

 

Terminal resistance 120

Ω 

  1 

 

Warranty card 

  1 

Feature

 

 

Support CAN2.0A and CAN2.0B protocol, in compliance 

with the ISO/DIS 11898 specification 

 

Bidirectional data communication between CAN-Bus and 

RS-232 

 

Integrated 1 CAN-Bus communication interface, support for 

user-defined baud rate 

 

Integrated 1 RS-232 three pins type communication 

interface, communication rate between 300~115200bps can 

be set 

 

Provide three kinds of data conversion modes: transparent 

conversion,  transparent with the identity conversion, 

Modbus protocol conversion 

 

CAN-Bus circuit using 2000V AC electrical isolation, 

support 8KV electrostatic protection (air discharge)   

 

CAN-Bus baud rate 2.5k~1Mbps 

 

Maximum frame rate: 500 frames per second 

 

DC9~48V wide voltage supply input, power supply support 

reverse connection 

 

IP40 protection grade, DIN-Rail or wall mounting 

installation 

 

-40-75

  working temperature 

Panel layout

 

 