Appendix 1-24
Appendix 1
List of Parameters
Parameter mode (code B)
*1) 1.80 × Inverter rated current (A)
*2) 1.50 × Inverter rated current (A)
Code
Name
Data range
Initial value
Note
Page
bA101
First frequency upper limit selection
00 (Disabling)/01 (Ai1 terminal input)/
02 (Ai2 terminal input)/
03 (Ai3 terminal input)/
04 (Ai4 terminal input)/
05 (Ai5 terminal input)/
06 (Ai6 terminal input)/
07 (Parameter setting)/
08 (RS485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)/
12 (Pulse string input (main body))/
13 (Pulse string input P1-FB)
00
bA102
First frequency upper limiter
0.00~590.00 (Hz)
0.00
bA103
First frequency lower limiter
0.00~590.00 (Hz)
0.00
bA110
First torque limit selection
00 (Disable)/01 (Ai1 terminal input)/
02 (Ai2 terminal input)/
03 (Ai3 terminal input)/
04 (Ai4 terminal input)/
05 (Ai5 terminal input)/
06 (Ai6 terminal input)/
07 (Parameter setting)/
08 (RS 485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)
07
12-11-8
bA111
First torque limit parameter mode selection
00 (Four quadrant specific)/
01 ([TRQ] terminal switch)
00
12-11-8
bA112
First torque limit 1
(Four quadrant normal powered)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
150.0
12-11-8
bA113
First torque limit 2
(Four quadrant reverse rotation regeneration)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
150.0
12-11-8
bA114
First torque limit 3
(Four quadrant reverse powered)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
150.0
12-11-8
bA115
First torque limit 4
(Four quadrant normal rotation regeneration)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
150.0
12-11-8
bA116
First torque LAD stop selection
00 (Disabled)/01 (Enabled)
00
12-11-8
bA120
First overcurrent suppression selection
00 (Disabled)/01 (Enabled)
01
12-13-3
bA121
First overcurrent suppression level
(0.00 to 2.00)
× Inverter rated current (A)
*1)
12-13-3
bA122
First overload limit 1 selection
00 (Disabled)/
01 (Accelerate at constant speed)/
02 (Only constant speed)/
03 (Accelerate at constant
speed/Increase speed at regeneration)
01
12-13-2
bA123
First overload limit level 1
(0.20 to 2.00)
× Inverter rated current (A)
*2)
12-13-2
bA124
First overload limit 1 operation time
0.10~3600.00 (s)
1.00
12-13-2
bA126
First overload limit 2 selection
00 (Disabled)/
01 (Accelerate at constant speed)/
02 (Only constant speed)/
03 (Accelerate at constant
speed/Increase speed at regeneration)
01
12-13-2
bA127
First overload limit level 2
(0.20 to 2.00)
× Inverter rated current (A)
*2)
12-13-2
bA128
First overload limit 2 operation time
0.10~3600.00 (s)
1.00
12-13-2
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...