12-9-22
Chapter 12
Inverter Function
Control operation in IVMS start mode
• IVMS start mode is a start mode where larger
torque is provided than in the synchronous starting
mode.
• When the synchronous starting mode provides an
insufficient torque, use of the IVMS start mode may
improve the performance.
• Use of the IVMS start mode requires an SM(PMM)
constant that is set by the sensorless vector control
and an adjustment dedicated for IVMS start mode.
• Before the motor drive, conduct an IVMS
auto-tuning and a test run with the load removed.
Parameters for IVMS start mode
• Some SM (PMM) may be unable to start in the
IVMS start mode.
• IVMS start mode is a control mode that requires a
strict adjustment. Please contact the sales officer of
our company if your motor cannot start.
• IVMS start mode requires a re-adjustment when the
inverter is replaced. When a malfunctioning inverter
needs to be restored immediately by replacing the
malfunctioning inverter with a new one, the
synchronous starting mode should be used.
• As the IVMS start mode is a very special control,
which may make a unique operation sound as the
starting sound.
Item
Parameter
Data
Description
IVMS carrier frequency
[Hd-41]
0.5~16.0(kH
z)
Set the carrier frequency during the IVMS drive.
Filter gain of IVMS
detection current
[Hd-42]
0~1000
The filter adjustment gain applied to the detection
current during the IVMS drive.
Open-phase voltage
detection gain selection.
[Hd-43]
00~04
The adjustment gain applied to the detection
voltage during the IVMS drivel.
Selection of open-phase
switch threshold correction.
[Hd-44]
00
IVMS correction: Disabled (no correction)
01
IVMS correction: Enabled (correction to be
conducted)
Speed control P gain
[Hd-45]
0~1000
Speed control P gain during the IVMS drive A larger
value enhances the responsiveness of the speed
control.
Speed control I gain
[Hd-46]
0~10000
Speed control I gain during the IVMS drive A larger
value enhances the responsiveness of the speed
control.
Waiting time for
open-phase switching
[Hd-47]
0~1000
Waiting time for the open-phase switching during
the IVMS drive. A larger value enhances the
stability.
Restriction on the
rotation-direction
determination
[Hd-48]
00
Rotation-direction determination: Disabled (no
restriction)
01
Rotation-direction determination: Enabled
(restricted to the operation-command direction)
Adjustment of the timing for
detecting the open-phase
voltage
[Hd-49]
0~1000
Adjustment value of the IVMS detection timing.
Minimum pulse-width
adjustment
[Hd-50]
0~1000
To adjust the width of the voltage pulse during the
IVMS drive. A larger value renders the pulse width
wider.
Current limit of IVMS
threshold
[Hd-51]
0~255
Set a limit on each of the upper and the lower limits
of the detection current during the IVMS drive.
Enabled when [Hd-44] = 01 (enabled).
IVMS threshold gain
[Hd-52]
0~255
To adjust the IVMS auto-tuning value.
IVMS carrier-frequency
switching start/finish point
[Hd-58]
0~50(%)
To adjust the point where the carrier frequency is
switched in the IVMS start mode.
A
!
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...