12-2-3
Chapter 12
Inverter Functions
12.2.2
Initialization of inverter
• Want to initialize the setting.
• Want to return to the factory setting.
• Want to initialize the setting except the terminal
block setting.
• Want to initialize the setting except the
communication setting.
• Want to clear the trip history only.
• When the initialization target [Ub-01] is chosen and
[Ub-05] Start Initialization is set to 01, the
designated data can be initialized to the factory
setting.
• Only the trip history can be cleared without
initialization of the stored parameter values.
Parameters
Content of [Ub-01] parameters chosen for
initialization
Item
Parameter range
Description
Classification
of I/O terminal
functions
[CA-01]
~
[CA-11]
Input terminal
selection
[CA-21]
~
[CA-31]
a/b contact selection
[CA-41]
~
[CA-51]
Input terminal
response
[Cb-40]
Thermistor selection
[CC-01]
~
[CC-07]
Output terminal
selection
[CC-11]
~
[CC-17]
a/b contact selection
[CC-20]
~
[CC-33]
Output delay
[CC-40]
~
[CC-60]
Logical operation
function
• Duty type selection (Ub-03) is not initialized.
• The initialization sets the parameters to initial
values. If the data before the initialization are
necessary, read the data using the R/W function
(Read) on the operator keypad or use PC software
to save the data on a PC.
• Initial values to be stored after the initialization can
be changed by changing the initial value selection
[Ub-02], For details of the modes, see a list of the
parameters attached to this document.
Item
Parameters
Data
Description
Selection of
initialization
[Ub-01]
00
The initialization is disabled.
01
The trip history and retry history are cleared.
02
All the parameters are all initialized.
03
The trip history, retry history, and all parameters are initialized.
04
The trip history, retry history, all parameters, and program data for EzSQ
are initialized.
05
Parameters other than those of I/O terminal function are initialized.
06
Parameters other than the communication function parameters are
initialized.
07
Parameters other than those of I/O terminal function and communication
function are initialized.
08
Only the program data for EzSQ are initialized.
Selection of
initial values
[Ub-02]
00
Mode 0
01
Mode 1
02
Mode 2
03
Mode 3
Initialization
start
[Ub-05]
00
Function disabled
01
Initialization start
Item
Parameter range
Description
Classification of
communication
functions
[CF-01]
~
[CF-10]
Setting of RS485
communication
[CF-20]
~
[CF-38]
Setting of EzCOM
communication
Q
A
!
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...