12-21-4
Chapter 12
Inverter Function
12.21.4
Outputting a signal when the
frequency reaches around 0 Hz
• I want to detect that the output frequency to the
motor has reached around 0 Hz and make a
notification to the system.
• Assign the output terminal function 040 [ZS] 0-Hz
detection signal to one of [CC-01] to [CC-07] that
corresponds to the output terminal and output the
signal.
• This function is to output a signal when the output
frequency of the inverter becomes lower than the
level specified with the 0-Hz detection value level
[CE-33].
• When the feedback circuit board is used, the actual
frequency of the motor is evaluated for outputting
the signal.
Parameter
• While the operation is stopped, the [ZS] signal
becomes ON state because the frequency is 0 Hz.
Item
Parameter
Data
Description
Output terminal
function selection
[CC-01]~[CC-05]
040
[ZS]: The 0-Hz signal is output to the
output terminal assigned.
Relay output
terminal function
selection
[CC-06]
Relay output
terminal function
selection
[CC-07]
0-Hz detection
value level
[CE-33]
0.00~100.00(Hz)
The frequency setting value to estimate
0-Hz state when [ZS] is output.
Q
A
!
Output
Frequency
[ZS]
[CE-33]
Operation
command [FW]
ON
OFF
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...