12-25-7
Chapter 12
About the inverter function
12.25.4
Selecting data to be output
• I want to cause an analog output terminal to
perform an output as inverter information.
Selectable parameter codes
• The below table shows selectable parameter
codes.
• The output scale ranges are specified when bias
settings are each set to 0.0%, and gain settings
are each set to 100.0%.
• You can select, using some parameter codes, data
to be output to the Analog output Ao1-L and Ao2-L
terminals and the Digital pulse output FM-CM1
terminal.
• You can adjust the output scale ranges with bias
settings and gain settings.
• Using the bias function, you can output, from data
that can output "(±) data," "(-) data" in a range from
which outputting is available.
Code
Name
Output scale range (Corresponding to 0 to 10
V / 0 to 20 mA / 0 to 100%)
Remarks
dA-01
Output frequency monitor
0.00 to Maximum speed (Hz)
Outputting is possible
with (±).
dA-02
Output current monitor
(0.00 to 2.00) × Inverter rated current (A)
Outputting is possible
with (±).
dA-04
Frequency command
0.00 to Maximum speed (Hz)
Outputting is possible
with (±).
dA-10
Estimated speed value monitor
0.00 to Maximum speed (Hz)
Outputting is possible
with (±).
dA-15
Torque command monitor
0 to Motor rated torque × 500% (Nm)
Outputting is possible
with (±).
dA-16
Torque limit monitor
0 to Motor rated torque × 500% (Nm)
Outputting is possible
with (±).
dA-17
Output torque monitor
0 to Motor rated torque × 500% (Nm)
Outputting is possible
with (±).
dA-18
Output voltage monitor
0 to Rated voltage × 133% (V)
dA-30
Input power monitor
0.00 to Rated power × 200% (kW)
dA-34
Output power monitor
0.00 to Rated power × 200% (kW)
dA-40
DC voltage monitor
(200 V class) 0.0 to 400.0 (Vdc)
(400 V class) 0.0 to 800.0 (Vdc)
dA-41
Braking circuit (BRD) duty ratio
monitor
0.00~100.00(%)
dA-42
Electronic thermal duty ratio
monitor (motor)
0.00~100.00(%)
dA-43
Electronic thermal duty ratio
monitor (inverter)
0.00~100.00(%)
Q
A
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...