12-25-13
Chapter 12
About the inverter function
Analog monitor adjustment mode: [FM] output
• Setting the analog monitor adjustment mode
[Cd-10] to 01 fixes the output of the [FM] output
terminal.
(Example) Outputting the output current monitor with
the PWM output
• I want to perform outputting with a PWM output of
100% when a current corresponding to the inverter
rated current flows.
(The standard point is the inverter rated current.)
Code
Name
Output scale range
(Corresponding to 0 to 10 V
/ 0 to 20 mA)
dA-02
Output
current
monitor
(0.00 to 2.00) × Inverter
rated current (A)
Set [Cd-01]=00 and [Cd-03]=(dA-02). Setting
[Cd-10] to 01 outputs PWM from the [FM] terminal
in accordance with [Cd-12].
When the standard point at which you want to
perform outputs is the rated current value, since
the rated current has a maximum scale of Rated
current × 2.00, set a point that is half of it. First set
[Cd-12] to 50.0% (corresponding to the inverter
rated current).
In this state, since the full scale of the output current
monitor is Rated current × 2.00, the [FM] terminal
outputs PWM of 50% duty, which is an output at the
rated current (= Rated current × 2.00 × 50.0%).
• With the fixed output, an output set with [Cd-12] is
made for the full-scale value of the monitor
selected with [Cd-03].
Adjust the inclination with [Cd-14]. Change
[Cd-14] to make an adjustment toward the point
from which PWM of 100% duty is output.
(For example, see and wait with a range from
190.0
%
to 210.0
%
.)
[Cd-13]=0.0%
、
[Cd-14]=200.0%
Returning [Cd-10] to 00 starts the PWM output of
[FM] that is adjusted.
1
2
3
4
Output current (A)
t/T(%)
100
0
Rated current × 2
(A)
0A
50
Rated current (A)
[Cd-14]=200.0%
Output current (A)
t/T(%)
100
0
Rated current × 2
(A)
0A
50
Rated current (A)
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...