18-36
Chapter 18
Tips/FAQ/Troubleshooting
18.5.2
Checking setting inconsistencies
• A warning was generated. You want to identify the
cause and troubleshoot the warning.
• You need to take a measure according to the
warning number and the type of warning. Refer to
the table below.
• The induction motor (IM) control and synchronous
motor (permanent magnetic motor) (SM (PMM))
control can be switched in [AA121].
Q
A
Warning was
generated -
102
(First Max. frequency) < (first upper limiter)
IM: [Hb105] < [bA102]
SM (PMM): [Hd105] < [bA102]
• Increase the Max. frequency
[Hb105]/[Hd105].
• Decrease the upper limiter [bA102].
Warning was
generated -
106
(First Max. frequency) < (first main speed command)
IM: [Hb105] < [Ab110]
SM (PMM): [Hd105] < [Ab110]
• Increase the Max. frequency
[Hb105]/[Hd105].
• Decrease the main speed command
[Ab110].
Warning was
generated -
103
(First Max. frequency) < (first lower limiter)
IM: [Hb105] < [bA103]
SM (PMM): [Hd105] < [bA103]
• Increase the Max. frequency
[Hb105]/[Hd105].
• Decrease the lower limiter [bA103].
Warning was
generated -
107
(First Max. frequency) < (first auxiliary speed command)
IM: [Hb105] < [AA104]
SM (PMM): [Hd105] < [AA104]
• Increase the Max. frequency
[Hb105]/[Hd105].
• Decrease the auxiliary speed
command [AA104].
Warning was
generated -
202
(Second Max. frequency) < (second upper limiter)
IM: [Hb205] < [bA202]
SM (PMM): [Hd205] < [bA202]
• Increase the Max. frequency
[Hb205]/[Hd205].
• Decrease the upper limiter [bA202].
Warning was
generated -
206
(Second Max. frequency) < (second main speed
command)
IM: [Hb205] < [Ab210]
SM (PMM): [Hd205] < [Ab210]
• Increase the Max. frequency
[Hb205]/[Hd205].
• Decrease the main speed command
[Ab210].
Warning was
generated -
203
(Second Max. frequency) < (second lower limiter)
IM: [Hb205] < [bA203]
SM (PMM): [Hd205] < [bA203]
• Increase the Max. frequency
[Hb105]/[Hd105].
• Decrease the lower limiter [bA103].
Warning was
generated -
207
(Second Max. frequency) < (second auxiliary speed
command)
IM: [Hb205] < [AA204]
SM (PMM): [Hd205] < [AA204]
• Increase the Max. frequency
[Hb205]/[Hd205].
• Decrease the auxiliary speed
command [AA204].
Occurrence
Estimated cause(s)
Exemplar measures to be taken
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...