12-14-2
Chapter 12
Inverter Function
12.14.2
Starting with DC braking
• How to start after having rotation fan stopped
• How to start operation after having rotating motor
stopped
• Before outputting the frequency to the motor, apply
DC braking to stop the motor rotating. And then,
start operation.
• To use DC braking for starting, the following
settings are required:
- Set [AF101] DC braking selection to 01
- Set [AF102] Braking mode selection to 00
- Set [AF109] DC braking time for starting to
other than 0.0
• In DC braking for starting, DC braking is performed,
after the operation command is given, for the
period of time set for the DC braking time for
starting [AF109].
Parameter
• If [AF101] DC braking selection is set to 02, DC
braking will be started when both the frequency
command and the output frequency become equal
to or lower than [AF103]
DC braking frequency setting
,
regardless of whether the motor is running or
stopped. See “12.15.2 Stopping with DC braking”
for details.
• Depending on the set braking force, the carrier
frequency may automatically go down to protect
the inverter.
• When setting or operating [AF108] DC braking
force for starting and [AF109] DC braking time for
starting, pay attention to heat generation on the
motor.
Example of a case where the DC braking function
for starting is applied
• If [AF102] Braking mode selection is set to other
than 00, see "12.14.9 Starting after applying
servo-lock".
Item
Parameter
Data
Description
DC braking selection
[AF101]
00
Internal DC braking: Disabled
01
Internal DC braking: Enabled
02
Internal DC braking: Enabled (operable only at the
set frequency)
Braking mode selection
[AF102]
00
Enables the DC braking.
DC braking force for
starting
[AF108]
0~100(%)
Adjusts the DC braking force. The maximum braking
force is achieved when set to 100%.
DC braking time for
starting
[AF109]
0.0~60.0(s)
Valid when the internal DC braking is enabled.
Starts the DC braking when the operation command
is turned on.
Q
A
!
!
[AF109]
DC braking
FW
Output
frequency
ON
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...