12-17-8
Chapter 12
Inverter Functions
Brake Control 2
• The brake control by managing time is available.
• The 037[BRK] brake release signal for the output
terminal function and the 037[BOK] brake check
signal for the input terminal function are available.
• [AF130] = 03: For the brake control function 2, the
following parameters are valid.
Brake Control 2 Function
The inverter starts the output and performs the
servo lock for the servo lock time at start.
(If the [AA121] control method is neither 09: zero
speed range sensorless vector control nor 10:
vector control with sensor, the DC braking is
applied.)
After the brake release delay time passes, the
brake release signal 037[BRK] is turned on.
The operation varies depending on whether the
brake check signal 037[BOK] is set to the input
terminal function.
After the servo lock time at start passes, there is
an acceleration.
With
[BOK]
setting
If the 037[BOK] is not turned on during the
brake check time, the inverter trips with the
[E036] brake error outputting the fault signal
038[BER].
Without
[BOK]
setting
After the release signal 037[BRK] signal is
turned on, there is a waiting for the servo lock
time at start to pass.
• Since the brake control 2 generates the servo lock status
when the brake is on, use 09: zero speed range
sensorless vector control or 10: vector control with sensor
for the [AA121] control method.
• Selecting the control methods other than the above will
replace the operation part of the servo lock with the DC
braking operation.
• For the brake control 2, an error occurs with a trip
in the following cases.
-
When the brake check signal 037[BOK] is used, [BOK] was not
turned on within the brake check waiting time at start-up.
- When the brake check signal 037[BOK] is used, [BOK] was not
turned off within the brake check waiting time at stop.
- When the brake check signal 037[BOK] is used, the brake
release signal 037[BRK] was being output, but [BOK] was
turned off.
Once the operation command is turned off, the
inverter decelerates and perform the servo lock.
The servo lock is kept for the servo lock time at
stop.
After the brake apply delay waiting time passes,
the brake release signal 037[BRK] is turned on.
The operation varies depending on whether the
brake check signal 037[BOK] is set to the input
terminal function.
There is a waiting for the servo lock time to pass.
With
[BOK]
setting
The inverter turns off the release signal
037[BOK], and if the 037[BOK] is not turned off
during the brake check time, the inverter trips
with the [E036] brake error outputting the fault
signal 038[BER].
Without
[BOK]
setting
After the release signal [BRK] signal is turned
off, there is a waiting for the servo lock time at
stop to pass.
Item
Valid for both
forward and reverse
Brake release delay time
[AF150]
Brake apply delay time
[AF154]
Brake check time
[AF152]
Servo lock time at start
[AF153]
Servo lock time at stop
[AF154]
▼
(1)
(2)
(3)
!
(4)
(5)
(6)
(7)
Operation
command
Output
frequency
Brake release delay time
(1)
(6)
(7)
(4)
Brake release signal
037[BRK]
Brake check signal
037[BOK]
Brake check time
Brake check time
(2)
Servo lock
time at start
Brake apply delay time
(3)
Servo lock
time at stop
(5)
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...