background image

Sterling Power Products

Copyright 

Optional

remote control

with 10 meter

cable 

(Part No 

SWR

)

Pure Sine Wave Inverters

Pro 

Power SB (R) 

Pure

sine wave

output

EN60950-1
EN55022: A2:2003 CLASS B
EN55024:2003
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
IEC61000-4-2:A2:2003
IEC61000-4-3:20002/A1:2002
IEC61000-4-4:2004
IEC61000-4-6:A1:2004
IEC61000-4-8:A1:2000

e

8

3000W - 5000W

Copyright © 2016 
Sterling Power 

V1.0 June 2016

RoHS

compliant

www.sterling-power.com

www.sterling-power-usa.com

Warranty (2 years return to factory)

WARNING:

DO NOT OPEN UNIT | HIGH INTERNAL VOLTAGE | PLEASE READ AND UNDERSTAND THE INSTRUCTIONS PRIOR 

TO INSTALLING OR OPERATING THIS PRODUCT | SHOULD ONLY BE INSTALLED BY A QUALIFIED PERSON 

Part No:

SIB12(24)3000
SIB12(24)4000
SIB12(24)5000

12V 

DC 

4

 

L : DUR

A

A

IT

B

IG

L

E

 D

 

 :

 :D

C I

E

M

S

A

G

I

N

N

Y

D

ProDigital 

Technology

D

WARNING: Do not open
High internal voltage

please read and understand instructions
before operating or installing this unit

Designed and developed in England:

 Made in China

Sterling Power Products Ltd.

www.sterling-power.com

www.sterling-power-usa.com

Pure sine wave inverter

Power SB

Pro

Live

Earth

Neutral

To AC appliances

Battery 

+

_

Fuse

Simply connect the positive and negative terminal of the inverter to the 12V 
or  24V  battery  terminals.  Use  an  appropriate  fuse  in  the  positive  line. 
Connect  the AC  appliance  to  the AC  socket  (up  to  3000W  through  the 
sockets - even if you have the 4KW / 5KW unit). The 

Live Earth Neutral 

studs under the bottom right panel can be used to fasten AC cable down for 
use  in  a  distribution  panel  (max  5000W  through  the  appropriate  sized 
cable). Then flick the on/off switch to turn on the inverter.  

To AC distribution

 Basic Installation

Summary of Contents for Pro Power SB Series

Page 1: ...000 SIB12 24 5000 12V DC 4 L DUR A A IT B I G L E D D C I E M S A GI N N YD ProDigital Technology D WARNING Do not open High internal voltage please read and understand instructions before operating or installing this unit Designed and developed in England Made in China Sterling Power Products Ltd www sterling power com www sterling power usa com Pure sine wave inverter Power SB Pro Live Earth Neu...

Page 2: ...Device connects to common negative Common negative must be earthed Ÿ In case of fire use a fire extinguisher suitable for electric fires Ÿ Ensure reverse polarity and short circuiting is avoided to prevent damage to battery Ÿ Protect DC andAC wires with the appropriate sized fuse Ÿ Check cabling annually fix where needed Ÿ Avoid contact with device with damp hands on DC side Ÿ Ensure the device is...

Page 3: ...size per unit in specification 6 Secure the unit in position fit DC fuse and isolation switch not essential as required 7 Do not reverse the DC cables Connect the red cable to the positive terminal and the black cable to the negative terminal of the battery reverse polarity could destroy the unit and would not be covered under warranty 8 The standard sockets are rated at 13A So you should NOT atte...

Page 4: ... from us Please review the documentation included with your purchase Our warranty only covers orders purchased from Sterling Power We cannot accept warranty claims from any other Sterling Power distributor Purchase or other acceptance of the product shall be on the condition and agreement that Sterling Power USA LLC and Sterling Power LTD shall not be liable for incidental or consequential damages...

Page 5: ... DUR A A IT B I G L E D D C I E M S A GI N N YD ProDigital Technology D WARNING Do not open High internal voltage please read and understand instructions before operating or installing this unit Designed and developed in England Made in China Sterling Power Products Ltd www sterling power com www sterling power usa com Pure sine wave inverter Power SB Pro Phase Schutzleiter Neutral Zum Geräteansch...

Page 6: ...s mit einem FI Schalter und LS Schaltern ACHTUNG WARNUNG EXPLOSION Sicherheitshinweise Spezifikation Sicherheits Symbole Inhaltsverzeichnis Seite 1 Schnell Installation Seite 2 Hinweise bitte lesen Spezifikation Seite 3 Anschluss Zeichnung Installations Zeichnung Installations Procedere Seite 4 Kabel und Sicherungen Wechselrichter Limits Fehler Optionale Fernbedienung Kundenservice und Garantie 2 ...

Page 7: ...lüfteten und sicheren Ort so nah wie möglich an den Batterien 2 Das Gerät muss mit mindestens 4 Schrauben befestigt werden 3 Vergewissern Sie sich dass die Kabel ausreichend dimensioniert sind 4 Installieren Sie eine Sicherung in die Plus Leitung zum Wechselrichter 5 Niemals die DC Kabel verpolen Das rote Kabel verbinden Sie mit Plus das schwarze Kabel mit Minus Eine Verpolung zerstört das Gerät u...

Page 8: ...nd Befestigungswand bestätigen Ÿ Alle Anschlüsse am Ladegerät fest sind und keine Kabel lose herumhängen Ÿ Korrosion von Anschlüssen und Kabeln Ÿ Kabelzustand und Befestigung Ÿ Batteriezustand und Kontrolle des Wasserstandes bei offenen Blei Säure Batterien Ÿ Batterietemperatur während des Ladevorganges Diese darf nicht viel höher sein als die Umgebungstemperatur Fehlerbehebung und Reparatur Sollt...