Summary of Contents for PIC2KVA Series

Page 1: ...ad Zhonghe Dist New Taipei City 235 TAIWAN R O C TEL 886 2 8226 5158 FAX 886 2 82265150 http www asian electron com e mail yukae ms35 hinet net PIC2KVA Series 19 Rack mount Pure Sine Wave Inverter with build in Battery Charger Instruction Manual ...

Page 2: ... 2 4 Quick hook up and testing 7 2 5 AC safety grounding 9 2 6 Making DC wiring connections 10 2 7 Inverter operation 10 2 8 Cooling fan working code 12 3 Maintenance 13 4 Troubleshooting guide 13 5 Warranty 14 6 Important safety striations 6 1 General safety precautions 14 6 2 Precautions when working with batteries 15 7 Appendices A 7 1 Dip switch 15 7 2 Tune VR 15 ...

Page 3: ...rature 1 1 Utilities Application 1 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors 1 1 2 Office equipment computers printers monitors facsimile machines scanner 1 1 3 Household items vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines 1 1 4 Kitchen appliances microwave ovens refrigerators and freezers coffee makers ...

Page 4: ...40V Tune VR Input Voltage Regulation 10 16 VDC 20 32 VDC 42 62 VDC 10 16 VDC 20 32 VDC 42 62 VDC Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Digital Display OVP UVP OTP OLP VAC AMP WATT VDC TEMP Hz Interface Control Port RS 232C With Baud Rate 2400 4800 9600 19200 Switch Selectable AC Input AC110V 90 130V AC220V 180 260V AC Frequency 50Hz 60 Hz...

Page 5: ... in this manual before installing and using this model 2 1 Front Panel Operation 2 1 1 Front view 2 1 2 ON OFF switch Power ON OFF switch leave in the OFF position during installation 2 1 3 Function key When sequentially push Function Key it will display various status on the function screen such as VAC Amp watts and so on When malfunction is occurred its display will be flashed on the screen 2 1 ...

Page 6: ...ity connection will blow internal fuse and may damage the unit permanently WARNING Do not connect the 12V model to a 24V battery The unit will be destroyed immediately 2 2 3 RS 232C Connect to remote control unit option accessory or connect to computer to remote control working status WARNING Do not connect the AC source to the unit s AC output terminal do not connect AC load to the unit s AC inpu...

Page 7: ... chassis ground terminal to earth or to vehicle chassis using 8 AWG wire WARNING Operation of the unit without a proper ground connection may result in an electrical safety hazard WARNING Shock Hazard Before proceeding further carefully check the unit is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not connect the output terminals of the unit to...

Page 8: ...e unit when the cooling fan is operating 2 3 6 Close to batteries Avoid excessive cable lengths but do not install the unit in the same compartment as batteries Use the recommended wire lengths and sizes see section 2 6 Also do not mount the unit where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure that will damage the unit 2 4 Quick H...

Page 9: ...u will hear the continuous sound from internal alarm Then the AC voltage shows on the display It means the device has done the operation 2 4 6 Set the power switch to the OFF position the device shuts down completely 2 4 7 Please use a power meter to accurately measure the true output R M S voltage of the unit Our company uses a power meter such as IDRC CP 350 or ABM 2019 to measure our product CA...

Page 10: ...ter is in bypass mode this connection neutral of the unit s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your breaker panel as required 2 5 1 2 230V Models There is no connection made inside the unit from either the line or neutral conductor to the safety ground Ground Fault Circuit Interrupters GFCI S Installations in Recreational Vehi...

Page 11: ... the unit and will void warranty Increasing your DC cable size will help improve the situation Our company recommends the following cables for optimum unit performance apply both 120V and 230V versions Model No Wire AWG Inline Fuse YK PIC30122KVA 2 0 250A YK PIC30122KVAE 2 0 250A YK PIC15242KVA 1 0 125A YK PIC15242KVAE 1 0 125A YK PIC08482KVA 2 70A YK PIC08482KVAE 2 70A Also use only high quality ...

Page 12: ...tput Current indicator LED displays light on AMP as show as output current value 2 7 4 Output Watts indicator LED displays light on Watts as show as output watts value 2 7 5 Input DC Voltage indicator LED displays light on VDC as show as input DC voltage value 2 7 6 Temperature indicator LED displays light on TEMP as show as internal operating temperature value 2 7 7 Output Frequency AC indicator ...

Page 13: ...ate heat properly The power inverter will automatically back up once it has cooled off 2 7 11 Over Load Protection indicator OLP The overload indicator indicates that the power inverter has shut itself down When output voltage over its continuous voltage then must return to operate manually 2 8 Cooling Fan Working Code Cooling fan of inverter is through detecting output power and over temperature ...

Page 14: ...output voltage 110V 95 105VAC 220V 190 210VAC Using average reading voltmeter Use true RMS reading meter and cable Ref point 2 4 7 Load display OLP flash Over load Reduce load No output voltage Fault input voltage Low High input voltage Recharge battery check connections and cable Ref point 2 5 point 2 6 No output voltage Over temp indicator Load less than 1700W Thermal shutdown Improve ventilatio...

Page 15: ...ply including warranties of merchantability and fitness for a particular purpose Repair and replacement are your sole remedies and the company shall not be liable for damages whether direct incidental special or consequential even though caused by negligence or other fault 6 Important Safety Instructions WARNING Before you install and use your unit be to read and save these safety instructions 6 1...

Page 16: ...n 6 2 4 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or the like to metal causing a severe burn 7 Appendices A 7 1 Dip Switch in the side of the unit S1 FREQ Hz S2 S3 BAUD RATE ACV ADJ ON 60 ON ON 2400 H L 240V 200V OFF 50 OFF ON 4800 H L 120V 100V ON O...