User Manual
Factory-Link-SPE-M
Industrial SPE 100BASE-T1 Media Converter
INO_
F
ac
to
ry
-L
ink
-SPE
-M
_Use
r_
M
a
nu
al_V
1.
0.
do
cx
Page 1: ...User Manual Factory Link SPE M Industrial SPE 100BASE T1 Media Converter INO_Factory Link SPE M_User_Manual_V1 0 docx...
Page 2: ...T1 Cable Recommendation 6 5 2 Power Connector 7 5 2 1 Receptacle Specification 7 5 2 2 Pin Assignment 7 5 2 3 Power Cable Recommendation 7 6 Configuration 8 6 1 T1 Role DIP1 8 6 2 Auto Role Switch DI...
Page 3: ...INO_Factory Link SPE M_User_Manual_V1 0 docx 2022 09 10 3 12 Revision History Revision Date Change 1 0 05 27 2022 initial release version...
Page 4: ...ave detection eases the T1 link configuration Master slave role can also be set manually using a DIP switch The wide power supply range from 5V to 28V allows a hassle free installation in various envi...
Page 5: ...Surge and ESD Protection IEC 61000 4 2 ESD 30 kV Air Contact IEC 61000 4 5 Lightning 45 A 8 20 s USB ESD Protection IEC 61000 4 2 ESD 15 kV Air 8 kV Contact Network Interfaces PHYs 100BASE T1 PHY Broa...
Page 6: ...500 2812 tbd tbd Terminals Pin Signal Remark 1 Data P 2 Data N SHD Shield Connector Housing Description Manufacturer Structure Jacket Shield AWG T1 SPE IP20 1x2xAWG26 7 PUR 15m Harting 2x0 13mm2 yes y...
Page 7: ...utor Distributor Number Mating Plug 3Pos Terminal Block Plug 2 5mm 180 free hanging W rth Elektronik 691381030003 Digi Key 732 6056 ND Pin Signal Remark 1 PWR 5V 28V DC 2 GND 3 SHIELD Chassis GND Desc...
Page 8: ...iation 6 2 Auto Role Switch DIP2 DIP2 controls a proprietary Auto Role Switch function When turned on the Factory Link SPE M automatically determines the T1 link role master or slave This function is...
Page 9: ...it provides direct access to the register sets of the integrated PHYs It provides the following functions Controller 100BASE T1 connection 100BASE TX connection Media Converter Selection Firmware Info...
Page 10: ...cs Using the T1 PHY Cable Diagnostics cable faults and their distance from the device can be detected During the measurement the link is broken The distance measurement has a tolerance of 1 5m Cable D...
Page 11: ...been read entering the address data in the Device and Register fields Entering a value in this field will result in a write operation to the respective register Written values are read back and displa...
Page 12: ...RoHS Restriction of the use of certain hazardous substances dt Restriction of use certain dangerous substances 8 3 CE Marking The i novative Factory Link SPE M has the CE mark This device complies wi...