background image

 

INO_Factory-Link-SPE-M_User_Manual_V1.0.docx 

 

 

2022-09-10   

 

9 / 12 

 

Software 

The graphical user interface is intended for remote monitoring. It can also be used for testing and 
development  purposes  as  it  provides  direct  access  to  the  register  sets  of  the  integrated  PHYs.  It 
provides the following functions: 

Controller 

100BASE-T1 connection 

100BASE-TX connection 

 

Media Converter Selection 

 

Firmware Information 

 

Device Reset 

 

Link Status Monitoring 

 

Signal Quality Indicator (SQI) 
Monitoring 

 

Cable Diagnostics 

 

Read/Write  Access  to  PHY 
registers 

 

Link Status Monitoring 

 

Read/Write  Access  to  PHY 
registers 

 

 

 

 

Summary of Contents for Factory-Link-SPE-M

Page 1: ...User Manual Factory Link SPE M Industrial SPE 100BASE T1 Media Converter INO_Factory Link SPE M_User_Manual_V1 0 docx...

Page 2: ...T1 Cable Recommendation 6 5 2 Power Connector 7 5 2 1 Receptacle Specification 7 5 2 2 Pin Assignment 7 5 2 3 Power Cable Recommendation 7 6 Configuration 8 6 1 T1 Role DIP1 8 6 2 Auto Role Switch DI...

Page 3: ...INO_Factory Link SPE M_User_Manual_V1 0 docx 2022 09 10 3 12 Revision History Revision Date Change 1 0 05 27 2022 initial release version...

Page 4: ...ave detection eases the T1 link configuration Master slave role can also be set manually using a DIP switch The wide power supply range from 5V to 28V allows a hassle free installation in various envi...

Page 5: ...Surge and ESD Protection IEC 61000 4 2 ESD 30 kV Air Contact IEC 61000 4 5 Lightning 45 A 8 20 s USB ESD Protection IEC 61000 4 2 ESD 15 kV Air 8 kV Contact Network Interfaces PHYs 100BASE T1 PHY Broa...

Page 6: ...500 2812 tbd tbd Terminals Pin Signal Remark 1 Data P 2 Data N SHD Shield Connector Housing Description Manufacturer Structure Jacket Shield AWG T1 SPE IP20 1x2xAWG26 7 PUR 15m Harting 2x0 13mm2 yes y...

Page 7: ...utor Distributor Number Mating Plug 3Pos Terminal Block Plug 2 5mm 180 free hanging W rth Elektronik 691381030003 Digi Key 732 6056 ND Pin Signal Remark 1 PWR 5V 28V DC 2 GND 3 SHIELD Chassis GND Desc...

Page 8: ...iation 6 2 Auto Role Switch DIP2 DIP2 controls a proprietary Auto Role Switch function When turned on the Factory Link SPE M automatically determines the T1 link role master or slave This function is...

Page 9: ...it provides direct access to the register sets of the integrated PHYs It provides the following functions Controller 100BASE T1 connection 100BASE TX connection Media Converter Selection Firmware Info...

Page 10: ...cs Using the T1 PHY Cable Diagnostics cable faults and their distance from the device can be detected During the measurement the link is broken The distance measurement has a tolerance of 1 5m Cable D...

Page 11: ...been read entering the address data in the Device and Register fields Entering a value in this field will result in a write operation to the respective register Written values are read back and displa...

Page 12: ...RoHS Restriction of the use of certain hazardous substances dt Restriction of use certain dangerous substances 8 3 CE Marking The i novative Factory Link SPE M has the CE mark This device complies wi...