User Manual -Solar Pumping Inverter

1

SOLAR PUMPING INVERTER

USER MANUAL

VERSION - 2015

VERSION

V4.0

DATE

APRIL / 5 / 2015

PRODUCER

LEO

To ensure of your health, equipment and property, please read this chapter carefully before use the solar

pumping inverter and act in compliance with the instructions.

1

SAFETY DEFINITION:

Summary of Contents for HSPL110KH

Page 1: ...TER USER MANUAL VERSION 2015 VERSION V4 0 DATE APRIL 5 2015 PRODUCER LEO To ensure of your health equipment and property please read this chapter carefully before use the solar pumping inverter and act in compliance with the instructions 1 SAFETY DEFINITION ...

Page 2: ...stalled Vertically The height of the device installation should be over 1 1m or more and please establish the risk identified beside the device The ambient temperature 20 60 If Over 45 Please make sure well ventilated and the backside of inverter should be covered to make sure the air of fan is output from TOP of inverter Relative humidity 15 95 RH The device ONLY can be used to control the three ...

Page 3: ...ge H 380V L 220V 2200 Support Rated Power of Pump 2200W HSPL Company product code HOBER and Solar Pumping Inverter Solar AC Diesel Switcher HSAS 2200 H L A B A B AC Input Frequency A 50Hz B 60H H L AC Input Voltage H 380V L 220V 2200 Power 2200W HSAS Company product code HOBER and Solar AC Switcher Solar Pumping System Construction PARAMETERS Optional Optional Optional Optional ...

Page 4: ... Manual Solar Pumping Inverter 4 Table 1 NOTE Solar Panel s Power configured to 1 2 2 times of pump s power according to the pump s efficiency and sunshine of solar pumping system installed location WIRING ...

Page 5: ...User Manual Solar Pumping Inverter 5 Table 2 3 INSTRUCTIONS 3 1 Socket ...

Page 6: ...top Boot control and output flow size control 3 2 DC Input a Please refer to the Table 1 and check the input voltage whether within the standard or not Then input voltage can be measured by multi meter For example 220V AC output so the DC input voltage range is 250V 450V b To PV Panel to Input of pumping inverter can connect the switcher if needs c Please make sure the input negative and positive ...

Page 7: ... detect For example of Well Connecting Method Tank connect wire is the same 1 The longest length of reserved wire is for well low level of water detect 2 The middle length of reserved wire is for well middle level of water detect 3 The shortest length of reserved wire is for well high level of water detect Remarks The connection is not on basis of line color difference according to the length of r...

Page 8: ... 0 Verify the PW HOBER TECH HSPL22KH Run 13 26 02 11 15 Inverter State No Warning No Error Temp 35 0 Degree Water State Tank Empty Well Full Solar Low Power to Stop MinFreq 10 Hz 5 M Stop Time 20 M Solar Power Voltage 540 V Current 2 A Power 1 08 KW System Setting 1 Working Time 2 Solar Power 3 Dry Run Detect 4 Tank Sensor 5 Well Sensor 6 Output Freq 7 Output Voltage 8 Gprs Password 9 Time Calibra...

Page 9: ... frequency Current of AC to the pump AC Output Max 50 Frequency Hz Error History Error 32 11 43 02 09 15 More Clear All Machine ID 4015 MFD 17 15 Gprs Control PW 8618688958696 0 0 0 0 Verify PW First Error History Error 32 11 43 02 09 15 More Clear All Error History Error 32 11 43 02 09 15 More Clear All Time Calibrate H M M D Y 20 25 2 11 15 Error History Clear All Data ESC Enter More Clear All S...

Page 10: ...te Verify the Password to Enter the Setting Menu Original is 0000 System Setting UP Down to change Menu Item Working Time For Inverter working time set If the system time within this setting then work or else standby Low Power of Solar Panel to Protect the Pump Solar Panel output power is low and no water output in the morning dusk also in cloudy days Inverter State No Warning No Error Temp 35 0 D...

Page 11: ... the pump is 50Hz but the setting is Max 60Hz then pump will be damaged Max Output Voltage of AC Set the Max output Voltage Invalid for inverter that 220V output NOTE Please confirm your pump s parameter if the pump is 380V but the setting is Max 440V then pump will be broken GPRS Control Password The Password is used for Command Verification that send by GPRS System Time System Time Calibrate Sys...

Page 12: ... OFF AND FLOW CONTROL Startup Clockwise Output Freq Min to Max Shut Down Anticlockwise Output Freq Max to Min 3 7 GPRS Control Optional need the use it together with GPRS module of Hober Remote Control the Inverter By SMS SMS Sample 1 The SIM Car Number 2G Factory Reset Enter Back ESC Key to Back 1 2 3 4 5 ...

Page 13: ...Running Time and restart time 5 Update the Password for SMS control 6 SMS to Control the Inverter Off Stop output Attention The password in the SMS command is the one that your set The character and is necessary 4 Error Flag Display NOTE a express the status is true for example Error Flag is 8 indicate system inverter is over temperature ...

Page 14: ...es to a group Three Group in Parallel Total Voc is 92V Vmp 78V Total Watt is 1860W NOTE As the low power of pump efficiency is low will ask more power for input please use 4Groups 6 PACKAGING Inverter 1pcs DC Input Connector 2 12pcs according to the Table 2 Tank Sensor 1pcs Well Sensor 1pcs AC Output Connector 1pcs User Manual 1pcs ...

Page 15: ...eply within 24 hours The following situation does not belong to the quality warranty the user to alter the serial number and machine quality warranty label tag use environment does not meet the conditions of using Product be repaired or disassembled without our authorization The following situation not free fee the specific charging standard according the device material cost extra both in or out ...