12-25-11
Chapter 12
About the inverter function
[Cd-01] [FM] terminal output form selection is set to
00
• With the "Bias adjustment [Cd-13]" of the "PWM
output," you can bias Point 0 as shown in the below
figure.
(Example) PWM-outputting [dA-01] output frequency
monitor
• I want to perform outputting until a frequency
reaches the maximum frequency when the PWM
output is 100%.
[Cd-13]=0.0%,[Cd-14]=100.0%
(Example) PWM-outputting [dA-02] output current
monitor
• I want to perform outputting until a current reaches
the inverter rated current when the PWM output is
100%.
[Cd-13]=0.0%
、
[Cd-14]=200.0%
• With the "Gain adjustment [Cd-14]" of the "PWM
output," you can change an inclination as shown in
the below figure.
(Example) PWM-outputting [dA-18] output voltage
monitor
• I want to monitor the output voltage.
[Cd-13]=0.0%,[Cd-14]=133.0%
(Example) PWM-outputting [dA-17] output torque
monitor
• I want to apply a PWM output range from 0 to
100% in a torque range from -200 to 200%.
[Cd-12]=01
、
[Cd-13]=50.0%
、
[Cd-14]=50.0%
(Example) PWM-outputting [dA-17] output torque
monitor
• I want to apply a PWM output range from 0 to
100% in a torque range from 0% to ±200%.
[Cd-12]=00
、
[Cd-13]=0.0%
、
[Cd-14]=100.0%
Output scale
t/T(%)
100
0
Parallel
movement
Outputting will
be made in
this range.
[Cd-13]=50.0(%)
[Cd-13]=-50.0(%)
[Cd-13]=0.0(%)
Maxim
um
0
50
-50
Output
frequency (Hz)
t/T(%)
100
0
Maximum
frequency
60Hz
0Hz
50
30Hz
Output current (A)
t/T(%)
100
0
Rated current
× 2 (A)
0A
50
Rated current
(A)
[Cd-14]=200.0%
Full scale
(FS)
t/T(%)
100
0
Outputting will
be made in
this range.
[Cd-14]=200.0(%)
[Cd-14]=50.0(%)
[Cd-14]=100.0(%)
Maximum
0
50
-50
[Cd-14]=-50.0(%)
Change in
inclination
Output voltage (V)
t/T(%)
100
0
Motor rated voltage
200 V
0V
50
100V
Output torque (Nm)
t/T(%)
100
-100
(+) rated torque
× 2
0
0
(-) rated torque
× 2
(+) rated torque
(-) rated torque
Outputting will
be made in
this range.
[Cd-13]=50.0%
[Cd-14]=50.0%
Output torque (Nm)
t/T(%)
100
-100
(+) rated torque × 2
0
0
(-) rated torque × 2
(+) rated torque
Outputting will
be made in
this range.
[Cd-13]=0.0%
[Cd-14]=100.0%
(+-) rated torque
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...