12-24-16
Chapter 12
About the inverter function
12.24.7
Performing resetting automatically
• I want to reset an error with an operation for which
an operation instruction is turned off.
• I want to perform starting up by releasing a trip
automatically when a releasable error occurs.
• When the "[bb-10] automatic reset selection" is set
to 01, resetting is performed after the "[bb-12]
automatic resetting stand-by time" has elapsed
from when an operation instruction has been turned
off.
• When the "[bb-10] automatic reset selection" is set
to 02, resetting is performed after the "[bb-12]
automatic resetting stand-by time" has elapsed
from when an error has occurred.
Example operation of automatic resetting
Example 1) When [bb-10]=01
*) When [bb-11]=00, the error output becomes the
"[AL] output."
Parameters
• When the "[bb-10] automatic reset selection" is set
to 01, resetting starts when the STOP/RESET key
is pressed as long as an instruction is given through
the operation panel.
• When resetting is performed manually, and a
control power supply is turned on again, the number
of automatic resetting counted in internal is cleared.
•
By setting the "Alarm output selection [bb-11]" to 01 while
automatic resetting is valid, you can invalidate the output
of the "Alarm [AL]" during automatic resetting operation.
• Upon automatic resetting has been performed for
the number of times set with the "[bb-13] automatic
resetting count setting," no error will be released,
but a trip occurs.
Example 2) When [bb-10]=02
Item
Parameter
Data
Description
Automatic reset selection
[bb-10]
00
Invalid
01
Resetting starts when the operation
instruction is turned
off.
02
Resetting starts after the set time has elapsed.
Alarm output selection
when the automatic
resetting is valid
[bb-11]
00
Outputting is available.
01
Outputting is not available.
Automatic resetting
stand-by time
[bb-12]
0~600(s)
Sets a stand-by time from when resetting starts to when
actual resetting starts.
Automatic resetting count
setting
[bb-13]
0 to 10 (times) Sets the number of automatic resetting.
Q
A
!
Output frequency
Operation
instruction [FW]
Error output*)
[bb-12]
Restarting in accordance with [bb-41]
Output frequency
Operation
instruction [FW]
Error output*)
[bb-12]
Restarting in accordance with [bb-41]
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...