Summary of Contents for APG3105

Page 1: ......

Page 2: ...carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick ...

Page 3: ...the owner s manual before operating this generator Operate only in well ventilated areas Exhaust gas contains poisonous carbon monoxide and can be deadly Always stop the engine before refueling Wait 5 minutes before restarting Check for spilled fuel or leaks Wait 5 minutes before use Keep any sources of ignition away from fuel tank at all times Indicates a strong possibility of severe personal inj...

Page 4: ...S 5 3 PRE OPERATION CHECK 8 4 STARTING THE ENGINE 11 5 USING THE GENERATOR 14 6 STOPPING THE ENGINE 17 7 MAINTENANCE 18 8 TRANSPORTING STORAGE 23 9 TROUBLESHOOTING 24 10 SPECIFICATIONS 26 11 WIRING DIAGRAM 27 12 WHEEL KIT 28 13 Part List 29 Owner s Manual 2 ...

Page 5: ...ation The muffler becomes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine To prevent scalding pay attention to the warning marks attached to the gen...

Page 6: ...ored the generator may explode burn or cause fire in the building s electrical system Always make a pre operation inspection before you start the engine You may prevent an accident or equipment damage Place the generator at least 3ft away from buildings or other equipment during operation Operate the generator on a level surface If the generator is tilted fuel spillage may result Know how to stop ...

Page 7: ... Fig 1 Outside view Fuel level indicator Air exhaust hole Top cover Air intake hole Rear cover Access door Starter grip Control panel Fuel filler cap Air intake hole Front cover LCD screen Operation button Side cover 3500W Digital Generator 5 ...

Page 8: ...ltaneously turn the ECON switch to the OFF position to reduce voltage changes ECON switch system does not operate efficiently if the electrical appliance requires the higher needed electric power OFF ECON switch does not operate Engine speed is kept over rated speed Grounding terminal Choke knob Start button Oil Alert Lamp Fuel valve lever Engine switch Econ switch Operation indicator green Overlo...

Page 9: ... the overload indicator yellow will go ON If there is a short in the connected appliance the AC DC output will be shut off automatically while the short circuit indicator red will be ON ALM operation button is used to reset the generator when short circuit occurs Press the DISP operation button once the LCD screen backlighting will remain ON for about 5 LCD screen back light DC switch AC switch LC...

Page 10: ... the average temperature in your area SAE Viscosity Grades Open the access door Remove the oil filler cap and wipe the dipstick with a clean rag Check the oil level by inserting the dipstick in the filler hole without screwing it in If the oil level is below the end of the dipstick refill with recommended oil up to the top of the oil filler neck Fig 4 Upper limit Lower limit single viscosity multi...

Page 11: ...be no fuel in the filler neck After refueling make sure the fuel filler cap is closed properly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry before starting the engine Avoid repeated or prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN 3 2 Check the fuel level Use automot...

Page 12: ...l since evidence of their suitability is as yet incomplete Before buying fuel from an unfamiliar station try to find out if the fuel contains alcohol if it does confirm the type and percentage of alcohol used If you notice any undersirable operating symptoms while using a gasoline that contains alcohol switch to gasoline that you know does not contain alcohol Fig 6 3 3 Check the air cleaner Check ...

Page 13: ...turn the fuel valve lever to the ON position then wait for 10 to 20 seconds before starting the engine Fig 8 4 2 Pull the choke knob out 4 1 Turn the fuel valve lever to the ON position see Fig 7 Fig 7 Do not use the choke when the engine is warm or the air temperature is high see Fig 8 Choke knob Fuel valve lever 3500W Digital Generator 11 ...

Page 14: ...e Fig 10 a 4 4 2 Pull the starter grip lightly until resistance is felt then pull the starter grip briskly toward the arrow as shown in Fig 10 b Do not allow the starter grip to snap back Return it slowly by hand Do not let the starter rope rub against the generator body or the rope will wear out prematurely Owner s Manual 12 ...

Page 15: ...e generator at altitude higher than 5 000 feet above sea level have your authorized agent to perform these carburetor modifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 1 000 feet increase in altitude The effect of altitude on the horsepower will be greater than this if no carburetor modification is made Operation of the generator at an a...

Page 16: ... cause fires in the building s electrical system Limit operation requiring maximum power to 10 minutes For continuous operation do not exceed the rated power In either case the total wattage of all appliances connected must be considered Do not modify or use the generator for other purposes than it is intended for Also observe the following when using the generator DO not connect generators in par...

Page 17: ... appliance to the generator check that it is in good order and that its electrical rating does not exceed that of the generator Fig 13 1 Confirm that the appliance to be used is switched off and plug in the appliance 2 Start the engine and press the AC button and make sure the output indicator light green comes on 5 2 operation overload and short circuit indicators The operation indicator green wi...

Page 18: ...nt the possibility of creating spark make sure to turn off the DC output before connect or disconnect charging cables Before connecting charging cable to a battery that is installed in a vehicle disconnect the vehicle grounded battery cable Reconnect the vehicle s ground battery cable after the charging cables are removed This procedure will prevent the possibility of a short circuit and sparks if...

Page 19: ...harging cord Do not reverse the charging cables or serious damage to the generator and or battery may occur To stop the engine in an emergency turn the engine switch OFF In normal use 1 Switch off the connected equipment and pull out the inserted plug 2 Turn off the engine switch 3 Turn the fuel valve lever to the OFF position 6 STOPPING THE ENGINE 3500W Digital Generator 17 ...

Page 20: ...o determine proper maintenance 2 Service more frequently when used in dusty areas 3 These items should be serviced by an authorized dealer unless the owner has the proper tools and is mechanically inclined ITEM REGULAR SERVICE PERIOD 1 Perform at every indicated month or operating hour interval whichever moccurs first EACH USE FIRST MONTH OR 20 HRS EVERY 3 MONTHS OR 50 HRS EVERY 6 MONTHS OR 100 HR...

Page 21: ...aled container to your local service station for proper disposal Do not throw it in the trash or pour it on the ground 7 3 Air filter servicing A dirty air cleaner will restrict air flow to the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas Do not use gasoline or low flash point solvents f...

Page 22: ...ueeze out the excess oil The engine will smoke during initial startup if too much oil is left in the sponge element Reinstall the sponge element to the air filter cover 4 Reinstall the air filter cover 5 Reinstall the rear cover two side covers and the access door in order 7 4 Spark plug service Recommended spark plug WR7DC To ensure proper engine operation the spark plug must be properly gapped a...

Page 23: ...oss threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress its washer If a used plug is being reinstalled it should only required 1 8 to 1 4 turn after being seated 9 Reinstall the spark plug inspection cover and tighten the cover screw 10 Close the access door Plug gap The spark plug must be securely tightened An improperly tightened s...

Page 24: ...1 Turn the access door knob left 1 4 turn open the access door Remove the two side covers and the rear cover 2 Remove the spark arrester 3 Use a brush to remove carbon deposits from the spark arrester screen Inspect the spark arrester screen for holes or tears Replace if necessary 4 Reinstall the spark arrester 5 Reinstall the rear cover two side covers and the access door in order Spark arrester ...

Page 25: ...fuel tank into a suitable container c Tighten the carburetor screw close the fuel valve lever and access door 3 Change the engine oil 4 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil then reinstall the spark plug 5 Slowly pull the starter grip until resistance is felt At this point the piston is com...

Page 26: ...fuel may ignite To check 1 Turn off the fuel valve and lossen the drain screw 2 Fuel should flow from the drain when the fuel valve is turned on Is the fuel reaching the carburetor Is the engine switch on Is the fuel valve on Is the enough oil in the engine Let the fuel inpour the carburetor Turn the engine switch on Turn the fuel valve on Add the recommended oil Is there sparks from the spark plu...

Page 27: ...ealer NO YES NO Is the operation indicator light ON Is the short circuit indicator light ON Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical appliance or equipment to an electrical shop for repair YES NO NO NO YES YES YES 3500W Digital G...

Page 28: ...Engine model Engine type Displacemet ml Bore x stroke mm x mm Rated speed r min Rated power kw Fuel type Fuel consumption g kwh Oil type Oil capaticy L Gal Starting type JF200 OHV250 single cylinder air cooled 4 stroke 196 68 x 54 3600 3 6 Automotive unleaded gasoline 395 SAE 10W 30 0 6 0 16 Electric Recoil starting Fuel tank capacity L Gal 10 5 2 8 Run time with rated output power h Noise level d...

Page 29: ...11 WIRING DIAGRAM Fig 21 3500W Digital Generator 27 ...

Page 30: ...wish to install the wheel kit please perform the following procedure a Uninstall the four rubber pads at the bottom of the chassis b Install the flange nut and universal wheel then repeat it until four wheels are installed Fig 22 Owner s Manual 28 universal wheel flange nut ...

Page 31: ...29 3500W Digital Generator ...

Page 32: ...r 17 APG3105 18 BOLD Fan 18 APG3105 19 BOLD Bolt 19 APG3105 20 BOLD Muffler 20 APG3105 21 BOLD Lower ventilation cover 21 APG3105 22 BOLD Cylinder head ventilation cover 22 APG3105 23 BOLD Bolt 23 APG3105 24 BOLD Bolt 24 APG3105 25 BOLD Fuel tank cover 25 APG3105 26 BOLD Sealing ring 26 APG3105 27 BOLD Top cover 27 APG3105 28 BOLD Fuel tank 28 APG3105 29 BOLD Bolt 29 APG3105 30 BOLD Handle 30 APG3...

Page 33: ...bber pad 57 APG3105 58 BOLD Bolt 58 APG3105 59 BOLD Cubic tube 59 APG3105 60 BOLD Bolt 60 APG3105 61 BOLD Bolt 61 APG3105 62 BOLD Lower liner tube 62 APG3105 63 BOLD Bolt 63 APG3105 64 BOLD Upper liner tube 64 APG3105 65 BOLD Rubber mat 65 APG3105 66 BOLD Stand 66 APG3105 67 BOLD Module 67 APG3105 68 BOLD Left cover 68 APG3105 69 BOLD Rear cover 69 APG3105 70 BOLD Bolt 70 APG3105 71 BOLD Operation...

Page 34: ...ith regard to this limited warranty shall be final This warranty gives you specific legal rights and you may also have other rights which vary from state to state RESPONSIBILITY OF ORIGINAL PURCHASER initial User To process a warranty claim on this product DO NOT return item to the retailer The product must be evaluated by an Authorized Warranty Service Center For the location of the nearest Autho...

Page 35: ...ble parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable periodof use Example Battery Spark Plug Air Filter Merchandise sold by All Power America which has been manufactured by and identified as the product of another company such as gasoline engines The product manufacturer s warranty if any will apply ANY INCIDENTAL INDIRECT OR CO...

Reviews: