12-10-10
Chapter 12
Inverter Functions
■
PID1 target value selection
Item
Parameter
Data
Description
PID1 target value 1 input
destination
[AH-07]
00~13
00: Invalid, 01: Ai1-L input, 02: Ai2-L input,
03: Ai3-L input, 04: Ai4-L input, 05: Ai5-L input,
06: Ai6-L input, 07: Parameter setting [AH-10], 08: RS 485
communication, 09: Option 1,
10: Option 2, 11: Option 3,
12: Pulse train input (main unit), 13: Pulse train input
(P1-FB)
PID1 target value 1 set value
[AH-10]
0.00~100.00[%]*1)
Is a parameter set value.
PID1 multi-layer target value 1
[AH-12]
PID1 multi-layer target value 2
[AH-14]
PID1 multi-layer target value 3
[AH-16]
PID1 multi-layer target value 4
[AH-18]
PID1 multi-layer target value 5
[AH-20]
PID1 multi-layer target value 6
[AH-22]
PID1 multi-layer target value 7
[AH-24]
PID1 multi-layer target value 8
[AH-26]
PID1 multi-layer target value 9
[AH-28]
PID1 multi-layer target value
10
[AH-30]
PID1 multi-layer target value
11
[AH-32]
PID1 multi-layer target value
12
[AH-34]
PID1 multi-layer target value
13
[AH-36]
PID1 multi-layer target value
14
[AH-38]
PID1 multi-layer target value
15
[AH-40]
PID1 target value 2 input
destination selection
[AH-42]
00~13
00: Invalid, 01: Ai1-L input, 02: Ai2-L input,
03: Ai3-L input, 04: Ai4-L input, 05: Ai5-L input,
06: Ai6-L input, 07: Parameter setting [AH-44], 08: RS 485
communication, 09: Option 1,
10: Option 2, 11: Option 3,
12: Pulse train input (main unit), 13: Pulse train input
(P1-FB)
PID1 target value 2 set value
[AH-44]
0.00~100.00[%]*1)
Is a parameter set value.
PID1 target value 3 input
destination selection
[AH-46]
00~13
00: Invalid, 01: Ai1-L input, 02: Ai2-L input,
03: Ai3-L input, 04: Ai4-L input, 05: Ai5-L input,
06: Ai6-L input, 07: Parameter setting [AH-48], 08: RS 485
communication, 09: Option 1,
10: Option 2, 11: Option 3,
12: Pulse train input (main unit), 13: Pulse train input
(P1-FB)
PID1 target value 3 set value
[AH-48]
0.00~100.00[%]*1)
Is a parameter set value.
PID1 target value operator
selection
[AH-50]
01
(Target value 1) + (Target value 2)
02
(Target value 1) - (Target value 2)
03
(Target value 1) x (Target value 2)
04
(Target value 1) / (Target value 2)
05
Minimum of deviation 1 (Target value 1 - FB 1), deviation
2 (Target value 2 - FB 2), and deviation 3 (Target value 3 -
FB 3)
06
Maximum of deviation 1 (Target value 1 - FB 1), deviation
2 (Target value 2 - FB 2), and deviation 3 (Target value 3 -
FB 3)
*1) Data range varies according to [AH-04] - [AH-06]
settings.
Summary of Contents for SJ Series
Page 39: ...5 4 Chapter 5 Included Items Memo ...
Page 55: ...6 16 Chapter 6 Installation Memo ...
Page 91: ...7 36 Chapter 7 Wire Connection and Optional Devices Memo ...
Page 135: ...9 40 Chapter 9 Operating Instructions Memo ...
Page 145: ...10 10 Chapter 10 Test Run Memo ...
Page 159: ...12 2 6 Chapter 12 Inverter Functions Memo ...
Page 169: ...12 3 10 Chapter 12 Inverter Functions Memo ...
Page 195: ...12 5 8 Chapter 12 Inverter Functions Memo ...
Page 217: ...12 8 12 Chapter 12 Inverter Function Memo ...
Page 287: ...12 10 32 Chapter 12 Inverter Functions Memo ...
Page 303: ...12 11 16 Chapter 12 Inverter Functions Memo ...
Page 349: ...12 15 8 Chapter 12 Inverter Function Memo ...
Page 395: ...12 17 34 Chapter 12 Inverter Functions Memo ...
Page 397: ...12 18 2 Chapter 12 Inverter Functions Memo ...
Page 415: ...12 19 18 Chapter 12 Inverter Function Memo ...
Page 581: ...15 10 Chapter 15 Optional Cassettes Memo ...
Page 591: ...16 10 Chapter 16 ProDriveNext EzSQ Memo ...
Page 642: ...18 49 Chapter 18 Tips FAQ Troubleshooting Memo ...
Page 650: ...19 8 Chapter 19 Maintenance and Inspection Memo ...
Page 781: ...Appendix 1 70 Appendix 1 List of Parameters Memo ...