background image

Summary of Contents for BOSS XL3

Page 1: ......

Page 2: ...1 Contents List 2 Odorox Boss XL3 Unit Operational Guidelines 3 Operating The Odorox Boss XL3 4 Care Instructions 5 Optic Replacement Instructions 6 Troubleshooting Guide 7 Specifications And Warranty 8 TABLE OF CONTENTS ...

Page 3: ...echanical adjustment or repair Use generator only for intended use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The use of attachments not recommended may cause hazards INDOOR USE ONLY NEVER block the air openings grills outlets or place on a soft surface such as a bed or sofa as this could cause the unit to tip ov...

Page 4: ...dorox Boss XL3 Hydroxyl Generator is shipped with the following 1 Odorox Boss XL3 Hydroxyl Generator 2 Washable Filter 3 Set of Keys 4 Owners Manual 5 Warranty Card Note Air Mover Not Included CONTENTS LIST ...

Page 5: ... chemical spills off gassing and any other odor problem you may encounter This unit allows you to decontaminate and deodorize while you dry because it joins directly to your existing air movers The Boss XL3 Unit is equipped with a selector switch for 2 or 3 Odorox hydroxyl generating optics and operates using very low Wattage For use in heavy odor concentrations the best performance will take plac...

Page 6: ...can be powered on by turning the PROCESSOR switch to the LOW or HIGH position refer to Note above The green PROCESSOR ON LED will indicate when the Boss XL3 Unit has either two or three Odorox hydroxyl generating optics functioning POWER OFF The main power for the Boss XL3 Unit can be switched off by turning the PROCESSOR switch to the OFF position PROCESSOR The Boss XL3 Unit is equipped with thre...

Page 7: ...eaned in the same manner as the exterior with the exception of the optics and optics housing OPTIC CLEANING Cleaning of the Odorox optics is recommended to maintain peak processing efficiency Fingerprints smudges dirt dust particles etc will interfere with the hydroxyl production and should be avoided Note Remove the optics from the optic chamber prior to cleaning to avoid any damage to the optics...

Page 8: ...Gently pull optic from three lamp supports Do not put any pressure on the side of the optic without support Caution Optics contain Mercury Dispose of optics in accordance with local regulations To find out more about local regulations please visit www lamprecycle org Step 5 Install new optic following these instructions Remove new optic from packaging and gently insert into the three optic clips W...

Page 9: ...to high speed Auxiliary air mover not rated for high enough static pressure low amperage unit Try the setup using an alternate auxiliary air mover Negative pressure tubing is kinked or not in the correct position to activate the pressure switch Ensure that the negative pressure tubing clear 1 4 inch is pulled through into the 7 inch discharge nozzle of the Boss XL3 Unit and that it is not kinked G...

Page 10: ...YL GENERATING OPTIC BROWN XSA00EW02 3 OPTICS POWER CABLE XSA00EA01 3 BALLAST ASSEMBLY 120 VOLT N Am XSA00EA06 3 BALLAST ASSEMBLY 200 277 VOLT 50 60 Hz INTL EPC IL 021 1 LIGHT MODULE PROTECTED LED 110 120VAC GREEN N Am EPC IL 017 1 LIGHT MODULE PROTECTED LED 230 240VAC GREEN INTL EPC IL 148 1 LIGHT MODULE PROTECTED LED 110 120VAC RED N Am EPC IL 149 1 LIGHT MODULE PROTECTED LED 230 240VAC RED INTL ...

Page 11: ...ibutor To find a distributor in your area please visit www Odorox com Odorox Hydroxyl Generators are proudly manufactured in the USA HGI Industries Inc 2055 High Ridge Road Boynton Beach FL 33426 Toll Free 877 735 3701 www hgiind com Copyright 2011 HGI Industries Incorporated Odorox and Boss XL3 are trademarks or registered trademarks of HGI Industries Incorporated Boynton Beach Florida USA ...

Reviews: