background image

 

 

TRP-C36 

 

User’s Manual 

 

Ethernet to RS232/422/485 Isolated Converter 

 

 

 
 
 
 

 

Printed Feb. 2006 Rev 1.1   

 

Trycom Technology Co.,Ltd 

1F, No.2-11,Sihu street ,Yingge Township, Taipei, Taiwan ROC

 

Tel: 886-2-86781191 , Fax: 886-2-86781172

 

Web: www.trycom.com.tw 

 

Copyright 

Copyright Notice: The information in this manual is subject to change without prior notice in order t o improve 
reliability, design and function and dosed not represent a commitment on the part of the manufacturer. No part of this 
manual may be reproduced, copied, or transmitted in any form without the prior written permission of manufacturer. 
Acknowledgment Products mentioned in this manual are mentioned for identification purpose only. Products manes 
appearing in this manual may or may not be registered trademarks or copyright of their respective companies   

Summary of Contents for TRP-C36

Page 1: ...ct to change without prior notice in order t o improve reliability design and function and dosed not represent a commitment on the part of the manufacturer No part of this manual may be reproduced copied or transmitted in any form without the prior written permission of manufacturer Acknowledgment Products mentioned in this manual are mentioned for identification purpose only Products manes appear...

Page 2: ...l Support 3000V DC isolation protection Auto direction flow control on RS 485 Supported baud rate up to 230 4Kbps Power Link TX RX mode LED indicator Support intranet and internet system setting function Support screw terminal and external DC power adaptor Operation system Windows Linux Mac DIN rail and panel mount support 1 2 Specification Power Input Voltage DC 10V to 30V Interface Standard RJ45...

Page 3: ...2 Hardware Description 2 1 TRP C36 Panel Layout 2 2 Block Diagram ...

Page 4: ...inal block or the power jack It supports 10 30V DC 500mA power supply When power is properly supplied the PWR LED will run indicating the power is up reading Warning User can only choose one of 2 power source External DC Jack or Screw terminal DC input Do not use external DC Jack and screw terminal DC input simultaneously 3 2 Ethernet Connection A straight through Ethernet cable can be used to con...

Page 5: ...422 485 serial device The wiring connection diagram is as below 4 Install software STOEC is the tool for user to configure the on line TRP C36 User may find the utility in the TRP C36 support CD Double click STOEC the install Shield Wizard will appear and guide you to complete installation ...

Page 6: ...4 3 Introduction of ETM utility Run STOEC utility ...

Page 7: ...tatus If TRP C36 was properly installed it will be detected and found If TRP C36 was improperly installed it will not be found or detected Notice To assure STOEC utility run detecting process it is highly recommended user close XP firewall protection software ...

Page 8: ...User can set IP address here Suppose user set IP address to be 192 168 0 112 Press OK The IP address change to 192 168 0 112 Warning 0 and 255 are invalid IP address for TRP C36 If we input these IP address TRP C36 will be locked ...

Page 9: ...Set Mask Click Set Mask button User can set Subnet Mask the process is same as Set IP IE Click IE button If the IP address same as TRP C36 IP address then Press OK into the login page ...

Page 10: ...OTICE TRP C36 hardware Gateway address must be same as the computer Gateway address or the Login frame will not be found Ping Click Ping button Press OK if ping successfully following page will be shown ...

Page 11: ... 5 How to configure TRP C36 Setup of TRP C36 is as easy as surfing on WWW no special software will be required The setup process can be easily done by popular Browsers such as IE or Netscape In the browser URL field set the IP address of device directly the login page will be shown ...

Page 12: ...administration password for authentication Factory default is empty However it is not recommended leave it empty in field operation TRP C36 uses the same password protection mechanism commonly used in Windows NT or UNIX If there are more than 3 consecutive times failure in password check during the login process the login function will be disabled even if user supply correct password the login wil...

Page 13: ... 255 0 is usually used for small network 255 255 0 0 for larger network If DHCP client mode is enabled and there s DHCP server on the network this field will be assigned by DHCP server automatically Gateway address Gateway IP addresses Gateway is a device which connects local network to external network If there s no gateway on the network just leave it as 0 0 0 0 If DHCP client mode is enabled an...

Page 14: ...o TCP server UDP UDP protocol connectionless 5 1 7 Socket port of digital I O Socket port of extra digital I O 5 1 8 Destination IP addresses Socket port The server IP address and socket port to be connected in TCP Client and UDP mode 5 1 9 Serial I O settings baud rate parity data bits stop bits Baud Rate 1200 115200 bps Parity None Even Odd Data bits 7 or 8 Stop Bit 1 or 2 Due to the limitation ...

Page 15: ...Report device ID when connected In TCP mode if report device ID enabled when socket connected TRP C36 will immediately report device ID in following formats Serial I O socket nnnnnA LF CR Digital I O socket nnnnnB LF CR The total length is 8 bytes Where nnnnn is 5 digit device ID assigned by user LF is decimal 10 CR is decimal 13 5 1 15 Setup password Administration password used in Login The pass...

Page 16: ...your applications need the latest release of firmware you will receive a Win32 executable software to upgrade the firmware in TRP C36 through network Connect TRP C36 device to LAN Firmware upgrade of TRP C36 will not work on Internet Set the target TRP C36 device to have IP address in the same subnet as your host computer In the DOS Prompt environment of Windows execute the upgrade software you re...

Page 17: ... Mode and Direct IP Mode 8 1 Paired Mode Paired mode is also called serial tunneling When this type of configuration is selected No additional software is needed to install in a host PC In fact a PC is not required to make the connection Any two dumb serial devices that can communicate with each other through a serial link will be able to communicate using two TRP C36 and the LAN Two TRP C36 are c...

Page 18: ...ss Socket port of serial I O 1001 TCP Client Socket port of digital I O 101 TCP Client Destination IP address Socket port TCP client and UDP 192 168 0 106 port 1001 The Client Destination IP address must be same as Server IP address 192 168 0 106 the Socket port number must be same as Server Socket port number 1001 8 2 Virtual Com Mode ...

Page 19: ...oint 9 will guide you setup Virtual COM mode 8 3 Direct IP Mode mode Direct IP connections allow applications using TCP IP or UDP IP network socket programs to communicate with the asynchronous serial port on the TRP C36 In this type of application the TRP C36 is configured to TCP or UDP server The socket program running on the PC establishes a communication connection with the TRP C36 The raw dat...

Page 20: ...PortConsolem2000 utility If user s operating system is Win XP or XP sp2 it is strongly recommended to disable XP firewall before running VserPortConsole Fig 1 If no Virtual RS 232 port exist the dialogue window is empty Move your mice cursor to the place under VirtualSerialPort Console click the mice right button you will see Fig 2 ...

Page 21: ...Fig 2 Select Add Port wait for a while you will see Fig 3 Fig 3 Click OK you will see Fig 4 Fig 4 Click OK go to Fig 5 you will find there is a Virtual RS 232 port ...

Page 22: ...rsor to the RS 232 port that you want to use for example COM 11 and click the mice right button you will see Fig 6 t Fig 6 Select Add Net you will see Fig 7 You can start the RS 232 port s TCP server TCP xlient or UDP setting ...

Page 23: ...tion by UDP protocol COM6 Go to Fig 6 select COM6 for Add Net setting Select UDP Fig 8 Set Local port 30000 IP 127 0 0 1 Remote port 31000 COM10 Go to Fig 6 Select COM10 for Add Net setting Select UDP Fig 8 Set Local port 31000 IP 127 0 0 1 Remote port 30000 ...

Page 24: ...Fig 8 After COM6 and COM10 setting you will see the Fig 9 Fig 9 Use TRPCOM utility to open the com port that you had already assigned You are able to proceed with data communication See Fig 10 ...

Page 25: ...ig 10 Click Terminal then input the command to RS 485 device or Test loop back you ll get response See fig 11 Fig 11 User can directly link TRP C36 to Trycom Remote IO Modules by RS 485 The basic wiring ...

Page 26: ...connect See Fig 12 Fig 12 ...

Reviews: