(4) Using the step operation
The following shows the procedure for checking positioning data using the step
operation.
(a) Turn ON the step valid flag before starting the positioning data.
(Write "1" (carry out step operation) in " Cd.26 Step valid flag".)
(b) Set the step mode before starting the positioning data.
(Set in " Cd.27 Step mode".)
(c) Turn ON the positioning start signal, and check that the
positioning control starts normally.
(d) The control will stop for the following reasons.
1) One step of positioning stopped normally. (Go to step (f))
2) Control stopped by a stop signal (Take appropriate measures, go to
step (e))
3) An error occurred and the control stopped. (Take appropriate
measures, go to step (c))
(e) Write "2" (restart) to "
Cd.28
Step start information", and check
that the positioning data where the control stopped operates
normally. (Go to (d)).
(f) Write "1" (step continue) to "
Cd.28
Step start information", and
check that the next positioning data where the control stopped
operates normally.
1) One step of positioning stopped normally. (Go to step (f))
2) Control stopped by a stop signal (Take appropriate measures, go to
step (e))
3) An error occurred and the control stopped. (Take appropriate
measures, go to step (c))
4) All positioning data operated normally (Go to step (g))
(g) Turn OFF the step valid flag, and quit the "step function".
(Write "0" (do not carry out step operation) in " Cd.26 Step valid flag".)
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......