5 DATA USED FOR POSITIONING CONTROL
[Table 1]
Pr.25
setting value
Value set with peripheral device
(ms)
Value set with sequence program
(ms)
0 : 1-word type
1 to 65535
1 to 65535*
1 : 2-word type
1 to 8388608
1 to 8388608
* 1 to 32767
: Set as a decimal
32768 to 65535 : Convert into hexadecimal and set
[Table 2]
Pr.1
setting value
Value set with peripheral device
(unit)
Value set with sequence program
(unit)
0 : mm
0.01 to 6000000.00 (mm/min)
1 to 600000000 (
×
10
-2
mm/min)
1 : inch
0.001 to 600000.000 (inch/min)
1 to 600000000 (
×
10
-3
inch/min)
2 : degree
0.001 to 600000.000 (degree/min)
1 to 600000000 (
×
10
-3
degree/min)
3 : pulse
1 to 1000000 (pulse/s)
1 to 1000000 (pulse/s)
Pr.32 JOG speed limit value
Set the maximum speed for JOG operation.
Note) Set the "JOG speed limit value" to less than " Pr.7 Speed limit value".
If the "speed limit value" is exceeded, the "JOG speed limit value error"
(error code: 956) will occur.
Pr.33 JOG operation acceleration time selection
Set which of "acceleration time 0 to 3" to use for the acceleration time during JOG
operation.
0 : Use value set in " Pr.8 Acceleration time 0".
1 : Use value set in " Pr.26 Acceleration time 1".
2 : Use value set in " Pr.27 Acceleration time 2".
3 : Use value set in " Pr.28 Acceleration time 3".
Pr.34 JOG operation deceleration time selection
Set which of "deceleration time 0 to 3" to use for the deceleration time during JOG
operation.
0 : Use value set in " Pr.9 Deceleration time 0".
1 : Use value set in " Pr.29 Deceleration time 1".
2 : Use value set in " Pr.30 Deceleration time 2".
3 : Use value set in " Pr.31 Deceleration time 3".
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......