14 - 21
MELSEC-A
14 TROUBLESHOOTING
Relevant buffer memory address
Axis 1
Axis 2
Axis 3
Setting range
(Setting given in sequence program)
Remedy
26 176 326
0,
1
27 177 327
0,
1
28
178
328
0, 1, 2
29
179
329
0: Manual pulse generator operation
ignored
1: Manual pulse generator connected to
axis 1 is used.
2: Manual pulse generator connected to
axis 2 is used.
3: Manual pulse generator connected to
axis 3 is used.
31 181 331
0: One-word type
1: Two-word type
Change the setting to within the setting range and turn
OFF then ON the PLC READY signal (Y1D).
15
165
315
0 to 255
Change the setting so that the movement per pulse
converted to the pulse count becomes fewer than 256
pulses. (Refer to section 12.3.1)
36
37
186
187
336
337
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
38
39
188
189
338
339
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
40
41
190
191
340
341
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
42
43
192
193
342
343
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
44
45
194
195
344
345
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
46
47
196
197
346
347
(One-word type)
1 to 65535
(Two-word type)
1 to 8388608
Change the setting to within the setting range and turn
OFF then ON the PLC READY signal (Y1D).
48
49
198
199
348
349
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
•
Change the setting to within the setting range and turn
OFF then ON the PLC READY signal (Y1D).
•
Change the setting to within the speed limit value.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......